分享
ASTM_D_1253_-_14_2021e1.pdf
下载文档

ID:183109

大小:107.50KB

页数:6页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_1253_ _14_2021e1
Designation:D125314(Reapproved 2021)1Standard Test Method forResidual Chlorine in Water1This standard is issued under the fixed designation D1253;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1NOTEThe WTO caveat was added editorially in December 2021.1.Scope1.1 This test method covers the determination of residualchlorine in water by direct amperometric titration.1.2 Within the constraints specified in Section 6,this testmethod is not subject to commonly encountered interferencesand is applicable to most waters.Some waters,however,canexert an iodine demand,usually because of organic material,making less iodine available for measurement by this testmethod.Thus,it is possible to obtain falsely low chlorinereadings,even though the test method is working properly,without the users knowledge.1.3 Precision data for this test method were obtained onestuary,inland main stem river,fresh lake,open ocean,andfresh cooling tower blowdown water.Bias data could not bedetermined because of the instability of solutions of chlorine inwater.It is the users responsibility to ensure the validity of thetest method for untested types of water.1.4 In the testing by which this standard was validated,thedirect and back starch-iodide titrations and the amperometricback titration,formerly part of this standard,were found to beunworkable and were discontinued in 1986.Historical infor-mation is presented in Appendix X1.NOTE1Orthotolidine test methods have been omitted because of poorprecision and accuracy.1.5 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3370 Practices for Sampling Water from Flowing ProcessStreamsD5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water Analysis3.Terminology3.1 DefinitionsFor definitions of terms used in this testmethod,refer to Terminology D1129.3.2 Definitions of Terms Specific to This Standard:3.2.1 combined residual chlorine,nresidual consisting ofchlorine combined with ammonia nitrogen or nitrogenouscompounds.3.2.2 free-available-chlorine residual,nresidual consist-ing of hypochlorite ions,hypochlorous acid,or a combinationthereof.3.2.3 total residual chlorine(chlorine residual),ntheamount of available chlorine-induced oxidants present in waterat any specified period,subsequent to the addition of chlorine.3.2.3.1 DiscussionChlorine present as chloride is neitherincluded in these terms nor determined by this test method.Bromine,bromine combined with ammonia or nitrogenouscompounds,and chlorine dioxide are not distinguished by thistest method from the corresponding chlorine compounds.4.Summary of Test Method4.1 This is an amperometric titration test method utilizingphenylarsine oxide as the titrant.When the titrator cell is1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.05 on Inorganic Constituentsin Water.Current edition approved Nov.1,2021.Published December 2021.Originallyapproved in 1953.Last previous edition approved in 2014 as D1253 14.DOI:10.1520/D1253-14R21E01.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1?immersed in a sample containing chlorine,current is generated.As phenylarsine oxide is added,the chlorine is reduced and thegeneration of curr

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开