分享
ASTM_D_1203_-_10.pdf
下载文档

ID:183094

大小:72.16KB

页数:3页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_1203_ _10
Designation:D120310Standard Test Methods forVolatile Loss From Plastics Using Activated CarbonMethods1This standard is issued under the fixed designation D1203;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1.Scope*1.1 These test methods cover the determination of volatileloss from a plastic material under defined conditions of timeand temperature,using activated carbon as the immersionmedium.1.2 Two test methods are covered as follows:1.2.1 Test Method A,Direct Contact with ActivatedCarbonIn this test method the plastic material is in directcontact with the carbon.This test method is particularly usefulin the rapid comparison of a large number of plastic specimens.1.2.2 Test Method B,Wire CageThis test method pre-scribes the use of a wire cage,which prevents direct contactbetween the plastic material and the carbon.By eliminating thedirect contact,the migration of the volatile components to thesurrounding carbon is minimized and loss by volatilization ismore specifically measured.1.3 The values stated in SI units are to be regarded as thestandard.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE1This standard is similar in content(not technically equivalent)to ISO 176.2.Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD883 Terminology Relating to PlasticsD1600 Terminology forAbbreviated Terms Relating to Plas-ticsE197 Specification for Enclosures and Servicing Units forTests Above and Below Room Temperature(Withdrawn1981)3E691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 Other Documents:ISO 176 Determination of the Loss of Plasticizers fromPlastics by the Activated Carbon Method43.Terminology3.1 DefinitionsDefinitions are in accordance with Termi-nologies D883 and D1600 unless otherwise indicated.4.Significance and Use4.1 The test methods are intended to be rapid empirical testswhich have been found to be useful in the relative comparisonof materials having the same nominal thickness.NOTE2When the plastic material contains plasticizer,loss from theplastic is assumed to be primarily plasticizer.The effect of moisture isconsidered to be negligible.4.2 Correlation with ultimate application for various plasticmaterials shall be determined by the user.To obtain acceleratedtests that more nearly approach actual service conditions,referto Specification E197.5.Apparatus5.1 BalanceAn accurate analytical balance,equipped withClass S weights or better.5.2 Oven or BathA thermostatically controlled oven orbath capable of maintaining the temperature to within 61C ofthe test temperature,which normally will be in the range from50 to 150C.1These test methods are under the jurisdiction of ASTM Committee D20 onPlastics and are the direct responsibility of Subcommittee D20.15 on ThermoplasticMaterials(Section D20.15.11 on Plasticizers).Current edition approved Nov.1,2010.Published January 2011.Originallyapproved in 1952.Last previous edition approved in 2003 as D1203 94(2003).DOI:10.1520/D1203-10.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4Available from American National Standards Institute(ANSI),25 W.43rd St.,4th Floor,New York,NY 10036,http:/www.ansi.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 5.3 ContainersMetal cans or wide-mouth screw-top jars,of cylindrical form,approximately 100 mm in diameter andapproximately12L in capacity.NOTE3Pint paint cans work well.5.4 MicrometerA micrometer capable of measuring to thenearest 0.0025 mm for measuring the thickness of the testspecimens.5.5 Metal Cages(for Test Method B)Wire cages con-structed from approximately 30-mesh bronze gauze,in cylin-drical form,having a diameter of 60 mm and a height of 6 mm,formed by soldering a strip of gauze at right angles to theperiphery of a disk of bronze gauze.One of the bases acts as alid.5.6 150 mL Beaker graduated in 10 mL intervals.6.Material6.1 Activated Carbon,614MeshIt has been found thatdifferent types and grades of activated carbon give differingresults,thus making it necessary for the purchas

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开