分享
ASTM_D_2741_-_95_2005.pdf
下载文档

ID:182839

大小:269.07KB

页数:5页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_2741_ _95_2005
Designation:D 2741 95(Reapproved 2005)Standard Test Method forSusceptibility of Polyethylene Bottles to SootAccumulation1This standard is issued under the fixed designation D 2741;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon(e)indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers the determination of the relativesusceptibility of polyethylene bottles to soot accumulation.1.2 The values stated in SI units are to be regarded asstandard.The values given in parentheses are for informationonly.NOTE1There is no similar or equivalent ISO standard.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.Specific precau-tionary statements are given in Section 8 and Note 7.2.Referenced Documents2.1 ASTM Standards:2D 618 Practice for Conditioning Plastics for TestingD 883 Terminology Relating to PlasticsE 104 Practice for Maintaining Constant Relative Humidityby Means of Aqueous Solutions3.Terminology3.1 Definitions:3.1.1 Standard definitions for plastics as they appear inTerminology D 883 shall apply.3.1.2 sootthe finely divided carbon rich particles resultingfrom incomplete combustion of an organic material.4.Summary of Test Method4.1 An electrostatic charge is generated on the bottle sur-face.Under controlled conditions,the charged samples areexposed in a chamber to soot created by burning toluene-wetted filter paper.Soot accumulation is rated visually bycomparing the amount of carbon particles accumulated on thebottle to that shown on a preestablished graded scale.5.Significance and Use5.1 This test method provides a useful means for determin-ing the relative susceptibility of polyethylene bottles to accu-mulate soot.In particular,this test method has been founduseful in evaluating antistatic additives or antistatic bottlesurface treatments,or both.Experience has shown that thebehavior of bottles in this test can be directly related to dustand lint accumulation under actual use conditions.5.2 This test method provides a means of accelerating sootaccumulation.However,the correlation of the results of thistest method to actual use conditions must be established foreach application.5.3 Although no formal round-robin testing has been doneon other types of plastics,this test method has been founduseful for testing other than polyethylene plastics.35.4 Before proceeding with this test method,referenceshould be made to the specification of the material being tested.Any test specimen preparation,conditioning,dimensions,ortesting parameters,or combination thereof,covered in thematerials specification shall take precedence over those men-tioned in this test method.If there are no material specifica-tions,then the default conditions apply.6.Apparatus6.1 Soot Test Chamber,having a 0.066-m3(2.3-ft3)testingvolume essentially like that shown in Fig.1 and Fig.2.Chambers of other design(normally larger or having multipletest chambers to allow testing of greater numbers of bottles atthe same time)that provide comparable results are consideredacceptable alternatives.With such chambers it is essential thatthe following items be sized and kept in direct proportion to thetotal test chamber volume:6.1.1 Blower or fan size,6.1.2 Amount of filter paper and toluene,and6.1.3 Amount of drying agent if required.1This test method is under the jurisdiction ofASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.20 on Plastic Products.Current edition approved July 15,2005.Published August 2005.Originallyapproved in 1968.Last previous edition approved in 2001 as D 2741-95(2001).2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Schanzle,R.E.,“New Test for Plastics Antistatics,”Modern Packaging,MOPAA,May 1964,pp.129,130,and 204.1Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959,United States.6.2 Manifold System has been proven desirable for uniformair circulation in larger units.Experience has shown that 0.05mLof toluene on 452 mm2of filter paper/0.028 m3(1 ft3)of testchamber volume produces a satisfactory smoke concentration.The test chamber shall be equipped with:6.2.1 Means for maintaining a 15 6 5%relative humidityatmosphere(Note 2),6.2.2 A fan or blower for air circulation,6.2.3 Means for igniting toluene wetted filter paper,and6.2.4 Removable 80-mesh wire screens covering test cham-ber inlet and outlet.NOTE2The test chamber described in this pr

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开