温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_2375_
_05_2011
Designation:D237505(Reapproved 2011)Standard Test Method forManganese in Paint Driers by EDTA Method1This standard is issued under the fixed designation D2375;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers a titrimetric determination ofmanganese in liquid paint driers that can be dissolved in atoluene-alcohol mixture and utilizes the disodium salt ofethylenediaminetetraacetic acid dihydrate(EDTA).1.2 This test method is not applicable to drier blends.1.3 All cations that can be titrated with EDTA in alkalinemedia interfere and must not be present in the sample.1.4 The values stated in SI units are to be regarded as thestandard.The values given in parentheses are for informationonly.1.5 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2D600 Specification for Liquid Paint DriersD1193 Specification for Reagent WaterE180 Practice for Determining the Precision of ASTMMethods for Analysis and Testing of Industrial and Spe-cialty Chemicals(Withdrawn 2009)3E300 Practice for Sampling Industrial Chemicals3.Summary of Test Method3.1 The liquid drier is dissolved in toluene and ethyl alcoholand treated with an excess of standard EDTA solution.Theexcess is titrated with standard zinc chloride solution usingEriochrome Black-T as the indicator.4.Significance and Use4.1 The amount of manganese drier used in oxidizing-typecoatings significantly affects their drying properties.This testmethod may be used to confirm the stated manganese contentof pure liquid manganese drier soluble in toluene-alcohol andmanufactured for use by the coatings industry.5.Apparatus5.1 Centrifuge,capable of developing 1000 to 2000 g.6.Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests.Unless otherwise indicated,it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.4Other grades may beused,provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.6.2 Purity of WaterUnless otherwise indicated,referencesto water shall be understood to mean reagent water conformingto Type II of Specification D1193.6.3 Ammonium Chloride(NH4Cl).6.4 Ammonium Hydroxide(sp gr 0.90)Concentrated am-monium hydroxide(NH4OH).6.5 l-Ascorbic Acid.6.6 Buffer SolutionAdd 350 mL of concentrated NH4-OH(sp gr 0.90)to 54 g of NH4Cl and dilute to 1 L with water.6.7 Eriochrome Black-T IndicatorTriturate 0.2 g of Eri-ochrome Black-T and 100 g of NaCl,and store the mixture ina tightly stoppered bottle.This mixture remains stable forseveral years.6.8 Ethyl Alcohol(95%),pure or denatured.1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings,Materials,and Applications and is the direct responsibility ofSubcommittee D01.21 on Chemical Analysis of Paints and Paint Materials.Current edition approved June 1,2011.Published June 2011.Originallyapproved in 1965.Last previous edition approved in 2005 as D2375 05.DOI:10.1520/D2375-05R11.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4Reagent Chemicals,American Chemical Society Specifications,AmericanChemical Society,Washington,DC.For suggestions on the testing of reagents notlisted by the American Chemical Society,see Analar Standards for LaboratoryChemicals,BDH Ltd.,Poole,Dorset,U.K.,and the United States Pharmacopeiaand National Formulary,U.S.Pharmacopeial Convention,Inc.(USPC),Rockville,MD.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 6.9 EDTA,Standard Solution(0.05 M)Dissolve 18.62 gof EDTA in water and dilute to 1 L.Store in a polyethylene orborosilicate glass bottle.6.10 Hydrochloric Acid(sp gr 1.19)Concentrated(hydro-chloric acid(HCl).6.11 Sodium Chloride(NaCl).6.12 Toluene.6.13 Zinc,Granular.6.14 Zinc Chloride,Standard Solution(0.05 M)Weigh3.2690 g of zinc to the nearest 0.5 mg and dissolve in 50 mLof dilute HCl(14 mL of concentrated HCl(sp gr 1.19)to 36mL of water).Warm if necessary.Dilute the zinc chloride(ZnCl2)solution to 1 L in a volumetric flask.M15 3.2690/65.37(1)where:M1=molarity of Z