温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_2921_
_98_2017
Designation:D292198(Reapproved 2017)Standard Test Method forQualitative Tests for the Presence of Water Repellents andPreservatives in Wood Products1This standard is issued under the fixed designation D2921;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers simple qualitative field orlaboratory tests to determine water repellency or the presenceof chlorinated phenol2preservative chemicals in wood prod-ucts that are specified to be water repellent preservative treated.1.2 The values stated in SI units are to be regarded asstandard.The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 U.S.Federal Specification:TT-W-572 Wood Preservative Water-Repellant32.2 NIST Standard:262-63 Water Repellent Preservative Non-Pressure Treat-ment for Mill Work43.Significance and Use3.1 Although chlorinated phenol-treated wood has becomeless common due to environmental concerns,repellent-treatedwood is commonly specified in construction.This test methodprovides a means to verify the presence of a significant level ofwater repellent protection.4.Apparatus4.1 Eyedropper,plastic squeeze bottle or similar means formetering drops of water.4.2 Flame Source,such as bunsen burner,butane torch,oralcohol burner.4.3 Copper Wire Coil Specimen Holder(or Other SuitableCopper Holder)A suitable copper wire coil can be made byusing a lead pencil as a mandrel to form a helix using copperwire of about 1.6 to 2.4 mm(116to332in.)in diameter.Leavea space of approximately the diameter of the wire between eachloop.The helix should be 19 to 25 mm(34to 1 in.)in length.Leave a pigtail of about 152 mm(6 in.)of wire at one end ofthe helix and form a loop of approximately 25 mm(1 in.)indiameter to be used as a holder for the coil.4.4 Sharp Knife.5.Water Repellent Test5.1 Place uncut wood items to be tested so that the end grainis exposed as a horizontal surface.If the end grain cannot be sopositioned,comparisons can be made on the flat grain but withless definitive results.5.2 With an eye dropper,or similar device,allow severaldrops of water to fall from about 13 mm(12in.)on the endgrain of the wood.Wait 5 min and then observe the degree ofpenetration.With flat grain or vertical grain surfaces,waitingperiods of 10 to 15 min may be necessary.5.3 Water drops that immediately flatten out,penetrate anddarken the wood,indicate that the wood has not been treatedwith a water repellent.5.4 Water drops that“bead-up”and remain as spheres,withlittle or no color change or penetration,indicate that the woodhas been treated with a water repellent.Water repellentpreservatives,meeting Fed.Spec.TT-W-572 and NBS Stan-dard 262-63,impart sufficient water repellency to the end grainof wood to cause water drops to bead up and form spheres.6.Preservative Test6.1 Chlorinated phenol based wood preservatives emit acharacteristic green flame upon pyrolysis within a ventilated1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings,Materials,and Applications and is the direct responsibility ofSubcommittee D01.52 on Factory Coated Wood Products.Current edition approved July 1,2017.Published July 2017.Originally approvedin 1970.Last previous edition approved in 2011 as D2921 98(2011).DOI:10.1520/D2921-98R17.2Pentachlorophenol,tetrachlorophenol and other chlorinated phenols.3Available from DLA Document Services,Building 4/D,700 Robbins Ave.,Philadelphia,PA 19111-5094,http:/quicksearch.dla.mil.4Available from National Institute of Standards and Technology(NIST),100Bureau Dr.,Stop 1070,Gaithersburg,MD 20899-1070,http:/www.nist.gov.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 copper envelope due to the release of chlorine and its conse-quent reaction with copper(Beilsteins test).Untreated woo