温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_4318
10
e1
D4318-101DIMENSIONSLETTERB4CADAEFMM2114085020.10.20.50.10.50.1LETTERGHKAL4NMM1013601060DEG20MINIMUM0.051DEGESSENTIAL DIMENSIONSBACK AT LEAST 15 MM FROM TIPNOTE:DIMENSION A SHOULD BE 1.9-2.0 AND DIMENSION DSHOULD BE 8.0-8.1 WHEN NEW TO ALLOW FORADEQUATE SERVICE LIFEH6+E RADIUSJD|FDSECTIONKFIG.3 Grooving Tool(Optional Height-of-Drop Gauge Attached)5010construction,combine the various components in such propor-.05tions that the resultant sample represents the actual construc-tion case.8.1.2 Where data from these test methods are to be used forcorrelation with other laboratory or field test data,use the same25material as used for those tests where possible.8.2 Specimen-Obtain a representative portion from thetotal sample sufficient to provide 150 to 200 g of materialpassing the 425-um(No.40)sieve.Free flowing samplesDIMENSIONS IN MILLIMETRES(materials)may be reduced by the methods of quartering orsplitting.Non-free flowing or cohesive materials shall beFIG.4 Height-of-Drop Gaugemixed thoroughly in a pan with a spatula or scoop and arepresentative portion scooped from the total mass by making8.Sampling and Specimenone or more sweeps with a scoop through the mixed mass.8.1 Samples may be taken from any location that satisfiestesting needs.However,Practices C702 and D75 and Guide9.Calibration of ApparatusD420 should be used as guides for selecting and preserving9.1 Inspection of Wear:samples from various types of sampling operations.Samples in9.1.1 Liquid Limit Device-Determine that the liquid limitwhich specimens will be prepared using the wet-preparationdevice is clean and in good working order.Check the followingmethod(10.1)must be kept at their as-sampled water contentspecific points.prior to preparation.9.1.1.1 Wear of Base-The spot on the base where the cup8.1.1 Where sampling operations have preserved the naturalmakes contact should be worn no greater than 10 mm(in.)stratification of a sample,the various strata must be keptin diameter.If the wear spot is greater than this,the base canseparated and tests performed on the particular stratum ofbe machined to remove the worn spot provided the resurfacinginterest with as little contamination as possible from otherdoes not make the base thinner than specified in 6.1 and thestrata.Where a mixture of materials will be used inother dimensional relationships are maintained.