分享
ASTM_D_3577_-_19.pdf
下载文档

ID:179729

大小:122.41KB

页数:4页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_3577_ _19
Designation:D357719Standard Specification forRubber Surgical Gloves1This standard is issued under the fixed designation D3577;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S.Department of Defense.1.Scope1.1 This specification covers certain requirements for pack-aged sterile rubber surgical gloves used in conducting surgicalprocedures.1.2 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.3 The following safety hazards caveat pertains only to thetest method portion,Section 8,of this specification:Thisstandard does not purport to address all of the safety concerns,if any,associated with its use.It is the responsibility of the userof this standard to establish appropriate safety,health,andenvironmental practices and determine the applicability ofregulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D412 Test Methods for Vulcanized Rubber and Thermoplas-tic ElastomersTensionD573 Test Method for RubberDeterioration in an AirOvenD3767 Practice for RubberMeasurement of DimensionsD5151 Test Method for Detection of Holes in MedicalGlovesD5712 Test Method for Analysis of Aqueous ExtractableProtein in Latex,Natural Rubber,and Elastomeric Prod-ucts Using the Modified Lowry MethodD6124 Test Method for Residual Powder on Medical GlovesD6499 Test Method for Immunological Measurement ofAntigenic Protein in Hevea Natural Rubber(HNR)and itsProducts2.2 Other Documents:ISO 2859 Sampling Procedures and Tables for Inspection byAttributes3U.S.Pharmacopeia43.Classification3.1 Type 1Gloves compounded primarily from naturalrubber latex.3.2 Type 2Gloves compounded from a rubber cement orfrom synthetic rubber latex.4.Materials and Manufacture4.1 Any rubber polymer compound that permits the glove tomeet the requirements of this specification.4.2 A lubricant that meets the current requirements of theU.S.Pharmacopeia for Absorbable Dusting Powder may beapplied to the glove.Other lubricants may be used if theirsafety and efficacy have been previously established.4.3 The inside and outside surface of the rubber surgicalgloves shall be free of talc.5.Significance and Use5.1 The specification is intended as a reference to theperformance and safety of rubber surgical gloves.The safe andproper use of rubber surgical gloves is beyond the scope of thisspecification.6.Sampling6.1 For referee purposes,gloves shall be sampled andinspected in accordance with ISO 2859.The inspection levelsand acceptable quality levels(AQL)shall conform to those1This specification is under the jurisdiction ofASTM Committee D11 on Rubberand Rubber-like Materials and is the direct responsibility of Subcommittee D11.40on Consumer Rubber Products.Current edition approved Nov.1,2019.Published December 2019.Originallyapproved in 1977.Last previous edition approved in 2015 as D3577 09(2015).DOI:10.1520/D3577-19.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute,25 West 43rd St.,4thFloor,New York,NY 10036.4U.S.Pharmacopeia,latest edition,Mack Publishing Co.,Easton,PA 19175.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 specified in Table 1,or as agreed between the purchaser and theseller,if the latter is more comprehensive.7.Performance Requirements7.1 Gloves,sampled in accordance with Section 6,shallmeet the following referee performance requirements:7.1.1 Comply with requirements for sterility when tested inaccordance with 8.2.7.1.2 Be free from holes when tested in accordance with 8.3.7.1.3 Have consistent physical dimensions in accordancewith 8.4.7.1.4 Have acceptable physical property characteristics inaccordance with 8.5.7.1.5 Have a powder residue limit of 2.0 mg in accordancewith 8.6.7.1.6 Have a recommended aqueous soluble protein contentlimit of 200 g/dm2

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开