分享
ASTM_D_3401_-_97_2022.pdf
下载文档

ID:179216

大小:78.32KB

页数:5页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_3401_ _97_2022
Designation:D340197(Reapproved 2022)Standard Test Methods forWater in Halogenated Organic Solvents and TheirAdmixtures1This standard is issued under the fixed designation D3401;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S.Department of Defense.1.Scope1.1 These test methods describe the use of the Karl Fischer(KF)titration for determination of water in halogenated or-ganic solvents and mixtures thereof.Water concentrations from2 ppm to 1000 ppm can be determined in these solvents.Twotest methods are covered as follows:1.1.1 Test Method A,Water Determination Using a Coulo-metric KF TitratorThe coulometric test method is known forits high degree of sensitivity(typically 10 g H2O)and shouldbe the test method of choice if water concentrations aretypically below 50 ppm or if only small amounts of sample areavailable for water determinations.This test method requiresthe use of equipment specifically designed for coulometrictitrations.1.1.2 Test Method B,Water Determination Using a Volumet-ric KF TitratorThe volumetric test method is a more tradi-tional approach to KF water determinations.Although titratorsare specifically designed for KF volumetric determinations,many automatic titrators on the market can be adapted toperform KF titrations.1.2 Either of these test methods can be used to determinetypical water concentrations(15 ppm to 500 ppm)found inhalogenated solvents.1.3 These test methods recommend the use of commerciallyavailable Karl Fischer titrators and reagents.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.For specific precautionary statements,see Sections 11 and 15.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standard:2E203 Test Method for Water Using Volumetric Karl FischerTitration3.Summary of Test Method3.1 In the Karl Fischer reaction,water will react with iodinein the presence of sulfur dioxide,alcohol,and an organic baseaccording to the following equation:H2O1I21SO21CH3OH13RNRNH!SO4CH312RNH!I(1)where RN=organic base.3.2 When the volumetric titration test method is used forthis determination,the halogenated sample is added to a KFsolvent that usually consists of sulfur dioxide and an aminedissolved in anhydrous methanol.This solution is titrated withan anhydrous solvent containing iodine.The iodine titrant isfirst standardized by titrating a known amount of water.3.3 In the coulometric titration test method,the sample isinjected into an electrolytic cell where the iodine required forthe reaction with water is produced by anodic oxidation ofiodide.With this technique,no standardization of reagents isrequired.3.4 In both test methods,the end point is determinedamperometrically with a platinum electrode that senses a sharpchange in cell resistance when the iodine has reacted with allof the water in the sample.4.Significance and Use4.1 High water concentrations can have a detrimental effecton many uses of halogenated solvents.1These test methods are under the jurisdiction of ASTM Committee D26 onHalogenated Organic Solvents and Fire Extinguishing Agents and are the directresponsibility of Subcommittee D26.04 on Test Methods.Current edition approved May 1,2022.Published May 2022.Originallyapproved in 1975.Last previous edition approved in 2017 as D3401 97(2017).DOI:10.1520/D3401-97R22.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.14.1.1 Water can cause corrosion and spotting when solventsare used for metal cleaning.4.1.2 Water can reduce the shelf life of aerosol formula-tions.4.1.3 Water can inhibit desired reactions when solvents areused in formulations.

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开