分享
ASTM_D_3764_-_22.pdf
下载文档

ID:179044

大小:334.80KB

页数:18页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_3764_ _22
Designation:D376422Standard Practice forValidation of the Performance of Process Stream AnalyzerSystems1This standard is issued under the fixed designation D3764;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.INTRODUCTIONOperation of a process stream analyzer system typically involves four sequential activities.(1)Analyzer CalibrationWhen an analyzer is initially installed,or after major maintenance hasbeen performed,diagnostic testing is performed to demonstrate that the analyzer meets themanufacturers specifications and historical performance standards.These diagnostic tests may requirethat the analyzer be adjusted so as to provide predetermined output levels for certain referencematerials.(2a)Correlation for the Same MaterialOnce the diagnostic testing is completed,process stream samples are analyzed using the analyzer system.For application where the processanalyzer system results are required to agree with results produced from an independent(primary)testmethod(PTM),a mathematical function is derived that relates the analyzer results to the primary testmethod results(PTMR).The application of this mathematical function to an analyzer result producesa predicted primary test method result(PPTMR),for the same material.(2b)Correlation forMaterial including Effect fromAdditional Treatment to the MaterialThe PPTMR in(2a)can beused as an input to a mathematical model to predict the effect of an additive and/or a blendstock addedto a basestock material as measured by a PTM.(3)Probationary ValidationAfter the correlation(s)relationship between the analyzer results and primary test method results has been established,aprobationary validation is performed using an independent but limited set of materials that were notpart of the correlation activity.This probationary validation is intended to demonstrate that thePPTMRs agree with the PTMRs to within user-specified requirements for the analyzer systemapplication.(4)General and Continual ValidationAfter an adequate amount of PPTMRs andPTMRs have been accrued on materials that were not part of the correlation activity,a comprehensivestatistical assessment is performed to demonstrate that the PPTMRs agree with the PTMRs to withinthe tolerances established from the correlation activities.Subsequent to a successful generalvalidation,quality assurance control chart monitoring of the differences between PPTMR and PTMRis conducted during normal operation of the process analyzer system to demonstrate that theagreement between the PPTMRs and PTMRs established in the General Validation is maintained.Thispractice deals with the third and fourth of these activities.“Correlation for material including effect from additional treatment to the material”as outlined inthis standard is intended primarily to be applied to biofuels where the biofuel material is added at aterminal or other facility and not included in the process stream material sampled by the analyzer atthe basestock manufacturing facility.The correlation shall be specific for a constant percentageaddition of the biofuels material to the basestock for each model.This practice may not apply forphysical properties where the source material for the biofuel material or the denaturant/diluentmaterial used with the biofuel material can significantly affect the finished biofuels physical property.The user of the standard should investigate the effect of changes to biofuels material blend ratios,biofuels material source material,and blendstock material composition when using this practice.Limits to any of these may need to be applied when the correlation is used.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.11.Scope*1.1 This practice describes procedures and methodologiesbased on the statistical principles of Practice D6708 to validatewhether the degree of agreement between the results producedby a total analyzer system(or its subsystem),versus the resultsproduced by an independent test method that purports tomeasure the same property,meets user-specified requirements.This is a performance-based validation,to be conducted usinga set of materials that are not used a priori in the developmentof any correlation between the two measurement systems underinvestigation.A result from the independent test method isherein referred to as a Primary Test Method Result(PTMR).1.1.1 The degree of agreement described in 1.1 can be eit

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开