分享
ASTM_D_3876_-_96_2013.pdf
下载文档

ID:178939

大小:77.47KB

页数:3页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_3876_ _96_2013
Designation:D387696(Reapproved 2013)Standard Test Method forMethoxyl and Hydroxypropyl Substitution in Cellulose EtherProducts by Gas Chromatography1This standard is issued under the fixed designation D3876;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method is applicable to the determination ofmethoxyl and hydroxypropyl substitution content in celluloseether products by a Zeisel-gas chromatographic technique.1.2 This test method is not suitable for use for the analysisof hydroxypropyl-cellulose due to its very high substitutionlevel.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.For specific hazardstatements,see Section 2,11.1.4,and 11.1.7.2.Summary of Test Method2.1 When methyl cellulose or hydroxypropyl methyl cellu-lose is reacted with hydriodic acid,1 mol of methyl iodide and1 mol of isopropyl iodide are liberated for each mole ofmethoxyl and hydroxypropoxyl that is substituted on thecellulose chain.The methyl iodide and isopropyl iodide areextracted in situ with o-xylene and quantitated by gas chroma-tography using an internal standard technique.3.Significance and Use3.1 This test method determines the methoxyl and hydroxy-propoxyl content of cellulose ethers by a Zeisel-gas chromato-graphic technique.3.2 Substitution levels affect solution properties,rheology,viscosity,and many other properties of the polymer.4.Apparatus4.1 Gas Chromatograph,2with thermal conductivity detec-tor and heated injection port.4.2 Electronic Integrator.34.3 Stainless Steel Tubing,49.5 mm in outside diameter and1981 mm in length,packed with reagent in 5.8.4.4 Syringes,10 and 100 L.4.5 Reaction Vials,Caps,and Heating Block.55.Reagents5.1 Purity of ReagentsReagent grade chemicals shall beused in all tests.Unless otherwise indicated,it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.6Other grades may beused,provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.5.2 o-Xylene,ACS.5.3 Toluene,ACS.5.4 Iodomethane,99%min.5.5 2-Iodopropane,97%min.5.6 Hydriodic Acid(sp.gr.1.69 to 1.70)57%.5.7 Acetone.5.8 Packing Material.76.Hazards6.1 Safety precautions must be taken for handling of hydri-odic acid.1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings,Materials,and Applications and is the direct responsibility ofSubcommittee D01.36 on Cellulose and Cellulose Derivatives.Current edition approved June 1,2013.Published June 2013.Originallyapproved in 1979.Last previous edition approved in 2007 as D3876 96(2007).DOI:10.1520/D3876-96R13.2Hewlett-Packard Model 5700,available from Hewlett-Packard,Route 41,StarrRd,P.O.Box 900,Avondale,PA19311,has been found satisfactory for this purpose.3Hewlett-Packard Model 3380 has been found satisfactory for this purpose.4Tubing from Supelco,Inc.,Supelco Park,Bellefonte,PA16823 has been foundsatisfactory for this purpose.5Reacti-therm Heating module,Reacti-Block Reacti-vials and Mininert valvetops from Pierce Chemical Co.,Box 117,Rockford,IL 61105 have been foundsatisfactory for this purpose.6Reagent Chemicals,American Chemical Society Specifications,AmericanChemical Society,Washington,DC.For Suggestions on the testing of reagents notlisted by the American Chemical Society,see Analar Standards for LaboratoryChemicals,BDH Ltd.,Poole,Dorset,U.K.,and the United States Pharmacopeiaand National Formulary,U.S.Pharmacopeial Convention,Inc.(USPC),Rockville,MD.7Columns packed with 10%SP2100 on 100/120 Supelcoport have been foundsatisfactory for this purpose.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 6.2 During the reaction,the glass vials are under pressure.Exercise caution in handling the hot vials.7.Sampling7.1 A specific sampling method is currently under study bythe subcommittee.8.Apparatus Preparation and Conditioning8.1 Install prepackaged columns in the chromatograph andcondition them by heating to 150C over 1 h and then holdingat temperature for 16 h.Then set the chromatograph asfollows:8Oven temperature130C isothermalInjection port temperature200CDetector temperature250CDetector current170 mAAttenuation1Carrier gasheliumColumn A20 mL/minColumn B20 mL/minNOTE1The conditions used here were determined to be optimum forthe column used.Optimum conditions should be determined for eachcolumn

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开