分享
ASTM_D_3828_-_16a.pdf
下载文档

ID:178919

大小:223.71KB

页数:10页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_3828_ _16a
Designation:D382816aStandard Test Methods forFlash Point by Small Scale Closed Cup Tester1This standard is issued under the fixed designation D3828;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S.Department of Defense.INTRODUCTIONThese small scale flash point methods are generally used for testing a sample at a specifictemperature where the specimen being tested and the airvapor mixture above it are close to thermalequilibrium.Test Method D3941 covers other flash point equipment operated at a specific temperature.Flash point values are a function of the apparatus design,the condition of the apparatus used,andthe operational procedure carried out.Flash point can therefore only be defined in terms of a standardtest method,and no general valid correlation can be guaranteed between results obtained by differenttest methods,or with test apparatus different from that specified.1.Scope*1.1 These test methods cover procedures for flash pointtests,within the range of 30 C to 300 C,of petroleumproducts and biodiesel liquid fuels,using a small scale closedcup tester.The procedures may be used to determine,whethera product will or will not flash at a specified temperature(flash/no flash Method A)or the flash point of a sample(Method B).When used in conjunction with an electronicthermal flash detector,these test methods are also suitable forflash point tests on biodiesels such as fatty acid methyl esters(FAME).1.2 The values stated in SI units are to be regarded as thestandard.The values given in parentheses are for informationonly.1.3 This standard should be used to measure and describethe properties of materials,products,or assemblies in responseto heat and flame under controlled laboratory conditions andshould not be used to describe or appraise the fire hazard orfire risk of materials,products,or assemblies under actual fireconditions.However,results of this test may be used aselements of a fire risk assessment which takes into account allof the factors which are pertinent to an assessment of the firehazard of a particular end use.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.Warning statementsappear throughout.See also the Material Safety Data Sheets forthe product being tested.2.Referenced Documents2.1 ASTM Standards:2D3941 Test Method for Flash Point by the EquilibriumMethod With a Closed-Cup ApparatusD4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD4177 Practice for Automatic Sampling of Petroleum andPetroleum ProductsD6299 Practice for Applying Statistical Quality Assuranceand Control Charting Techniques to Evaluate AnalyticalMeasurement System PerformanceD6708 Practice for Statistical Assessment and Improvementof Expected Agreement Between Two Test Methods thatPurport to Measure the Same Property of a MaterialE300 Practice for Sampling Industrial ChemicalsE1137/E1137M Specification for Industrial Platinum Resis-tance Thermometers2.2 ISO Standards:3Guide 34 General requirements for the competence of refer-ence material producers1These test methods are under the jurisdiction of ASTM Committee D02 onPetroleum Products,Liquid Fuels,and Lubricants and is the direct responsibility ofSubcommittee D02.08 on Volatility.Current edition approved Oct.1,2016.Published October 2016.Originallyapproved in 1979.Last previous edition approved in 2016 as D3828 16.DOI:10.1520/D3828-16A.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute(ANSI),25 W.43rd St.,4th Floor,New York,NY 10036,http:/www.ansi.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 Guide 35 Reference materialsGeneral and statistical prin-ciples for certificationEN ISO 3679 Determination of Flash PointRapid Equilib-rium Closed Cup MethodEN ISO 3680 Determination of Flash/No FlashRapidEquilibrium Closed Cup MethodISO 60751 Industrial Platinum Resistance Thermometersand Platinum Temperature Sensors2.3 Energy Institute Standards:4IP 523 Determination of Flash PointRapid EquilibriumClosed Cup MethodIP 524 Determination of Flash/No FlashRapid Equilib-rium Closed Cup Method3.Terminology3.1 Definitions:3.1.1 equilibrium,nin flash point test methods,the condi-t

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开