分享
ASTM_D_43_-_D_43M_-_00_2012e1.pdf
下载文档

ID:178671

大小:59.06KB

页数:2页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_43_ _D_43M_ _00_2012e1
Designation:D43/D43M00(Reapproved 2012)1American Association StateHighway and Transportation Officials StandardAASHTO No.:M121Standard Specification forCoal Tar Primer Used in Roofing,Dampproofing,andWaterproofing1This standard is issued under the fixed designation D43/D43M;the number immediately following the designation indicates the yearof original adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.A superscript epsilon()indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1NOTEUnits information was editorially corrected in June 2012.1.Scope1.1 This specification covers coal tar primer suitable for usewith coal tar pitch in roofing,dampproofing,and waterproofingbelow or above ground level,for application to concrete,masonry,and coal tar surfaces.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard.The values stated ineach system may not be exact equivalents;therefore,eachsystem shall be used independently of the other.Combiningvalues from the two systems may result in non-conformancewith the standard.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2D140 Practice for Sampling Bituminous MaterialsD168 Test Method for Coke Residue of Creosote(With-drawn 2006)3D246 Test Method for Distillation of Creosote and Creosote-Coal Tar Solutions(Withdrawn 2006)3D347 Tables for Volume and Specific Gravity Correction forCreosote,Creosote-Coal Tar Solution,and Coal Tar(Withdrawn 2006)3D367 Test Method for Xylene-Insoluble Matter in Creosote(Withdrawn 2006)3D368 Test Method for Specific Gravity of Creosote andOil-Type Preservatives(Withdrawn 2006)3D370 Practice for Dehydration of Oil-Type Preservatives3.Physical Requirements3.1 Coal tar primer shall be a distillate of coal-gas tar orcoke-oven tar and shall conform to the following requirements:Waternot more than 1%Consistency at 5C 41Fentirely fluid and crystal freeASpecific gravity,38/15.5C 100/60F not less than 1.06Matter insoluble in benzenenot more than 0.5%Distillation,based on water-free oil:Up to 210C 410Fnot more than 1%Up to 235C 455Fnot more than 10%Up to 355C 670Fnot less than 65%Coke residuenot more than 2%AThe coal tar primer shall be rated as crystal free if no crystals are formed when100 mL of the sample is maintained at a temperature of 5C 41F for 3 h,in a 125mL Erlenmeyer flask,with occasional stirring.4.Sampling4.1 Sample the coal tar primer in accordance with PracticeD140.5.Test Methods5.1 Determine the properties enumerated in this specifica-tion in accordance with the following methods:5.1.1 WaterTest Method D370.5.1.2 Specific GravityTest Method D368.5.1.3 Matter Insoluble in XyleneTest Method D367.5.1.4 DistillationMethod D246.5.1.5 Coke ResidueTest Method D168.5.1.6 Volume and Specific Gravity CorrectionVolume andSpecific Gravity Correction Tables D347.6.Inspection6.1 Inspection of the material shall be agreed upon betweenthe purchaser and the supplier.1This specification is under the jurisdiction of ASTM Committee D08 onRoofing and Waterproofingand is the direct responsibility of Subcommittee D08.05on Solvent-Bearing Bituminous Compounds for Roofing and Waterproofing.Current edition approved May 1,2012.Published June 2012.Originallyapproved in 1917.Last previous edition approved in 2006 as D43 00(2006).DOI:10.1520/D0043_D0043M-00R12E01.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 7.Rejection and Resubmittal7.1 Failure to conform to any of the physical requirementsprescribed in this specification shall constitute grounds forrejection.In the case of rejection,the supplier shall have theright to reinspect the rejected material and resubmit the lot afterremoval of those packages not conforming to the requirements.8.Packaging and Package Marking8.1 All products shall be packaged and labeled in accor-dance with applicable regulations.8.2 Unless otherwise agreed upon between the supplier andpurchaser,each package shall be marked to indicate theapplicableASTM designation,name,brand or trademark of themanufacturer or supplier,and the net contents.9.Keywords9.1 coal tar;dampproofing;primer;roofing;waterproofingASTM International takes no position respecting the validity of any patent rights assert

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开