分享
ASTM_D_3934_-_20.pdf
下载文档

ID:178518

大小:86.78KB

页数:3页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_3934_ _20
Designation:D393420Standard Test Method forFlash/No Flash TestEquilibrium Method by a Closed-CupApparatus1This standard is issued under the fixed designation D3934;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.INTRODUCTIONASTM Flash Point Test Methods D56,D93,D3278,and D3941 are specified by governmentdepartments and agencies for determining whether liquids are flammable or combustible.Theseclassifications are used as the basis for regulating the handling and shipping of liquids.ISO/TC 35,Paints and Varnishes,and ISO/TC 28,Petroleum and Related Products,have issued ISO1516 as a common standard,applicable to paints,varnishes,petroleum,and related products.Thismethod is similar to ISO 1516 but uses standard ASTM cups and style and format.Test MethodsD3278 and D3828 operate on the equilibrium principle by using the Setaflash tester that has atemperature-control device.This test method does not determine the finite flash point but whether or not flashing occurs at asingle specified temperature.The latter determination is made more accurate by ensuring that the testis carried out only when the material under test and the air/vapor mixture above it are in approximateequilibrium at the specified temperature.1.Scope1.1 This test method covers the determination of whether aliquid complies with the closed-cup flash point requirements ingovernment regulations,or in specifications,or as agreedbetween the purchaser and the seller.1.2 This test method is limited to a temperature rangebetween 0 and 110C(32 and 230F).1.3 The values stated in inch-pound units are to be regardedas standard.The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4 WarningMercury has been designated by many regu-latory agencies as a hazardous substance that can causeserious medical issues.Mercury,or its vapor,has beendemonstrated to be hazardous to health and corrosive tomaterials.Use caution when handling mercury and mercury-containing products.See the applicable product Safety DataSheet(SDS)for additional information.The potential existsthat selling mercury or mercury-containing products,or both,is prohibited by local or national law.Users must determinelegality of sales in their location.1.5 This standard is used to measure and describe theresponse of materials,products,or assemblies to heat andflame under controlled conditions,but does not by itselfincorporate all factors required for fire hazard or fire riskassessment of the materials,products,or assemblies underactual fire conditions.1.6 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D56 Test Method for Flash Point by Tag Closed Cup Tester1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings,Materials,and Applications and is the direct responsibility ofASTM Subcommittee D01.21 on Chemical Analysis of Paints and Paint Materials.Current edition approved June 1,2020.Published June 2020.Originallyapproved in 1982.Last previous edition approved in 2014 as D3934 14.DOI:10.1520/D3934-20.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.D93 Test Methods for Flash Point by Pensky-MartensClosed Cup TesterD3278 Test Methods for Flash Point of Liquids by SmallScale Closed-Cup Apparatus(Withdrawn 2020)3D3828 Test Methods for Flash Point by Small Scale ClosedCup TesterD3941 Test Method for Flash Point by the EquilibriumMethod With a Closed-Cup ApparatusE1 Specification for ASTM Liquid-in-Glass ThermometersE1137 Specification for Industrial Pla

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开