分享
ASTM_D_4590_-_18.pdf
下载文档

ID:178177

大小:79.36KB

页数:4页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_4590_ _18
Designation:D459018Standard Test Method forColorimetric Determination of p-tert-Butylcatechol In StyreneMonomer or AMS(Methylstyrene)by Spectrophotometry1This standard is issued under the fixed designation D4590;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope*1.1 This test method is applicable to the determination ofresidual 4-tertiary-butylcatechol(TBC)in styrene monomer orAMS in the 1 to 100 mg/kg range.Any other compoundproducing color at 490 nm when contacted with aqueoussodium hydroxide solution will interfere.It may be compen-sated for by including it in the preparation of the standardsolutions,if its identity and concentration in the sample areknown.1.2 In determining the conformance of the test results usingthis method to applicable specifications,results shall berounded off in accordance with the rounding-off method ofPractice E29.The limit of detection is 0.2 mg/kg while thelimit of quantitation is 0.8 mg/kg based on the ILS data inTable 1.1.3 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.For specific statements on hazards,see Section 8.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD3437 Practice for Sampling and Handling Liquid CyclicProductsD4790 Terminology of Aromatic Hydrocarbons and RelatedChemicalsD6809 Guide for Quality Control and Quality AssuranceProcedures for Aromatic Hydrocarbons and Related Ma-terialsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 Other Document:OSHA Regulations,29 CFR paragraphs 1910.1000 and1910.120033.Terminology3.1 See Terminology D4790 for definition of terms used inthis standard.4.Summary of Method4.1 Color is developed in the specimen by the addition ofcaustic in a methanol-octanol solvent.The intensity of the pinkcolor is measured with a spectrometer and compared to acalibration curve for quantitation.5.Significance and Use5.1 This test method is suitable for determining the quantityof TBC inhibitor,both for the protection against polymeriza-tion while in transit and storage,and for internal qualitycontrol.1This test method is under the jurisdiction of ASTM Committee D16 onAromatic,Industrial,Specialty and Related Chemicals and is the direct responsi-bility of Subcommittee D16.07 on Styrene,Ethylbenzene and C9 and C10AromaticHydrocarbons.Current edition approved June 1,2018.Published June 2018.Originallyapproved in 1986.Last previous edition approved in 2013 as D4590 13.DOI:10.1520/D4590-18.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from U.S.Government Printing Office Superintendent of Documents,732 N.Capitol St.,NW,Mail Stop:SDE,Washington,DC 20401,http:/www.access.gpo.gov.*A Summary of Changes section appears at the end of this standardCopyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 6.Apparatus6.1 Visible Range Spectrometer,equipped with absorptioncells providing light paths from 1 to 5 cm for use at approxi-mately 490 nm.6.2 Volumetric Pipets and PipetorsThe sample pipet vol-ume should be sized to fill the spectrometer absorption cell.Pipetor volumes must be scaled to the sample volume.Thisprocedure is written using a 15 mL sample volume.Thefollowing table shows how reagent pipetor volumes could bescaled to use a 5 mL sample volume.Sample Pipet,mL0.15 NaOHPipetor,LMethanol Pipetor,L1530060051002007.Reagents and Materials7.1 Purity of ReagentsReagent grade chemicals shall beused in all t

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开