分享
ASTM_D_4299_-_83_scan.pdf
下载文档

ID:178147

大小:486.38KB

页数:6页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_4299_ _83_scan
Designation:D 4299-83 4 m -70 AMERICAN SOCIETY FOR TESTING AND MATERIALS 1916 Race St.,Philadelphia,Pa.19103 Reprinted from the Annual Book of ASTM Standards,Copyright ASTM If not listed in the current combined index,will appear in the next edition.Standard Test Methods far EFFECT OF BACTERIAL CONTAMINATION ON PERMANENCE OF ADHESIVE PREPARATIONS AND ADHESIVES FILMS This standard is issued under the fwd designation D4299;the number immediately following the designation indicates the year of original adoption or,in the ose of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.A superscript epsilon(e)indicates an editorial changesince the last revision or reapproval.1.scope 1.1 These test methods cover the determina-tion of the effect of bacterial contamination on the permanency of:1.1.1 Adhesive Preparations,by determining the comparative viscosities and observing the appearance of the uncontaminated and the con-taminated adhesives when tested under defined conditions,and 1.1.2 Adhesive Films,.by exposure to cultures of selected species of bacteria growing on agar plates.1.2 The test methods are not appropriate for all adhesives.The presence of certain biocides might yield false negative tests as a result of irreversible reaction with the medium constitu-ents.Also,the efficacy of some biocides may change in storage due to the chemical and ther-mal environment to which they are subjected as components of certain adhesives.These test methods also are not designed to cover the pos-sibility of water soluble biocides leaching out of the giue line,so they are not appropriate for determining the effect of mold contamination on adhesives under water-soaking conditions.1.3 This standard may involve hazardous ma-terials,operations,and equipment.This standard does not purport to address all o f the safity prob-lems associated with its use.It is the responsibil-ity o f whoever uses this standard to consult and establish appropriate safety and health practices and determine the applicability o f regulatory limi-tations prior to use.Specific precautionary state-ments are given in Section 7.2.Applicable Documents 2.1 ASTMStandards:DI174 Test Method for Effect of Bacterial Contamination on Permanence of Adhesive Preparations and Adhesive Bonds E 1 Specification for ASTM Thermometers 2.2 TAPPI Method:T487 Fungus Resistance for Paper and 3.Description of Terms Specific to This Stand-ard 3.1 adhesive preparation-the adhesive in liq-uid form as supplied to the customer.3.2 adhesivefilm-the small portion of the adhesive prepared for use,which is spread in a thin layer on the sensitivity disks as described in 14.2.1.1,or the adhesive layer,%in.(3-mm)thick,which is cast on the tile squares as de-scribedin 14.3.1.1.4.Significance and Use 4.1 The test for the resistance of adhesive preparations to bacterial contamination(Section 13)is used to determine susceptibility of the adhesive to biodegradation.This method is useful in demonstrating whether an adhesive prepara-tion is sufficiently protected with biocide to resist attack by bacteria during its shelf life.It depends on changes in viscosity and physical appearance of the adhesive to provide indications of inade-Paperboard4 These test methods are under the jurisidiction of ASTM Committee DI4 on Adhesives and are the direct responsibility of Subcommittee D14.20 on Durability.Current edition approved Oct.28,1983.Published Febmary 1984.ReplacesD1174-51(1981).Discontinued,see 1983 Annual Book of ASTMStandards,Vol 15.06.Annual BookofASTMStandards,Vol 14.01.Available from TAPPI,P.O.Box 105113,Atlanta,GA 30348.1 NOTICE:This standard has either been superseded and replaced by a new version or discontinued.Contact ASTM International(www.astm.org)for the latest information.ASTM D4279 83 H 4.B quate protection.Laboratories not equipped to handle a more accurate microbiological deter-mination are generally capable of using this pro-cedure.This method is not suitable for use with mastic adhesives or with dry adhesives that are mixed with water at the time of use.4.2 The test for the resistance of adhesive films to bacterial attack(Section 14),provide an indi-cation of whether the adhesive will carry into the glue line sufficient antimicrobial properties to prevent attack by bacteria.See 1.2 for limitations on the effectiveness of this test.5.Apparatus 5.1 Antibiotic Sensitivity Disks,0.5 in.(13 mm)in diameter.5.2 Cylinder,500-mL capacity,graduated in 5-mL subdivisions.5.3 Constant Temperature Chamber,capable of being maintained at 95 f 1F(35 f OST)or 77 f 1F(25 f OST);or two chambers if needed simultaneously.5.4 Desiccators,two about i0 in.(254 mm)in inside diameter and 8 in.(203 mm)in height,with perforated porcelain plates to support the culture plates.5.5 Glass Rods,i2 in.(305 mm)in length,having a diameter of 0.25 in.(6.3 mm).5.6 Glass Rod,L-shaped,having the same dimensions as in 5.5,bent into an L at 2.75 in.(70 mm).5.7 Jar,round,i qt mason ja

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开