TM_D_4913_
_00_2016_rus
D 4913-00(2016.)STANDARD PRACTICE FOR DETERMINING CONCENTRATION OF HYDROGEN SULFIDE BY DIRECT READING,LENGTH OF STAIN,VISUAL CHEMICAL DETECTORS 2017 ():13.06.2017:3186-17/ASTM -,.9,-49,119049.:(499)236-54-49:(499)230-13-72 E-mail:interstgost.ru http:/www.interstandart.ru/(ASTM International)100 rr Harbor Drive,West Conshohocken,PA 19428,USA.ASTM International ,ASTM International.-,ASTM International ,.This translation is executed by FBU“CIC“Interstandard”of Federal Agency on Technical Regulating and Metrology under the license of American Society for Testing and Materials(ASTM International)100 rr Harbor Drive,West Conshohocken,PA 19428,USA.ASTM International does not approve and does not confirm these translations and in any cases only the English version published with a sign of ASTM International copyright can be considered as the original version.Reproduction of the specified translations by any Party,except for ASTM International or FBU“CIC“Interstandard”,is strictly forbidden according to the USA legislation and international copyright.ASTM D 4913-00(2016)1 D 4913-00(2016.)1 D 4913.,.().1.1.1 ,:(1),2 (2)(3).,-.,1 ASTM D22 ,D22.04 .1 2016.2016.1989.2011.D4913-00(2011).DOI:10.1520/D4913-00R16.2 (),.ASTM D 4913-00(2016)2 .1.2 .ASTM.1.3,.1.4 ,.,.2.2.1 ASTM:3 D 1356,D 3686 ()D 4490 D 4599 2.2 :3 ASTM,ASTM www.astm.org ASTM serviceastm.org.ASTM.Document Summary ASTM.ASTM D 4913-00(2016)3 CFR 1910.1000 29,1910.1000,Z,1926.55,D4 NIOSH ,19775 ,6 2.3 ANSI:7 ANSI/ISEA 102-1990(R1998)3.3.1 ,.D1356.4.4.1 ,.,4 ,732 N.Capitol St.,NW,Mail Stop:SDE,Washington,DC 20401.5 (NTIS),5285 Port Royal Rd.,Springfield,VA 22161,http:/www.ntis.gov.6 ,Inc.(ACGIH),1330 Kemper Meadow Dr.,Cincinnati,OH 45240,http:/www.acgih.org.7 (ANSI),25 W.43rd St.,4th Floor,New York,NY 10036,http:/www.ansi.org.ASTM D 4913-00(2016)4 ,.:4.1.1 ()1-10.4.1.2 (),1-8.(TWA).4.1.3 ;.1 8,TWA .4.2 ,.5.5.1 :,.,ASTM D 4913-00(2016)5 ,(),.5.2 29 CFR 1910.1000 ,.(NIOSH).5.3 .5.4 (TWA).6.,(1,4-9)6.1 5.6.2:6.2.1 .,.ASTM D 4913-00(2016)6 (10).6.2.2 (SEI).,SEI.NIOSH(11 13).6.2.3 ,.6.3:6.3.1 (.D4490).6.3.1.1 ,.().6.3.1.2 .6.3.1.3 ,.6.3.1.4 ASTM D 4913-00(2016)7 .,.6.3.1.5 .,.,.6.3.1.6 (),20-80%.6.4 ,.,.,.(TLV),(100).(TLV).ASTM D 4913-00(2016)8 ,.6.5 ,4C 40F 49C 120F 20%90%(14).().6.6 0,5 70 000.6.7 SEI ()25%,10 50.5 35%.,50,SEI ,25%.SEI ,25-35%.6.8 ,.7.(2,15,16)7.1 ().(TWA).ASTM D 4913-00(2016)9 7.2 ,5-20/,.7.3:7.3.1 .7.3.1.1 ,.7.3.1.2 .7.3.1.3 .7.3.1.4 .,.7.3.1.5 .D3686.7.3.1.6 ,/.7.3.1.7 ./(),ASTM D 4913-00(2016)10 ,.7.4 ,(.6.4).7.5 ,.7.6 0,5 100.7.7 ()25%(16).7.8 ,(.6.8).8.(3,17,18)8.1 TWA-,.0,5-8,0 ().8.2 ,.,.8.3:ASTM D 4913-00(2016)11 8.3.1 (.D 4599).8.3.1.1 .8.3.1.2 ,.8.3.1.3 .8.3.1.4 TWA-,.8.4 ,(.6.4),.8.5 10C 2%-,.(70%),.8.6 0,5 150.8.7 ()25%(3,18).ASTM D 4913-00(2016)12 8.8 ,(.6.8),.9.9.1 ;.(1)Littlefield J.B.,Yant W.P.Berger L.B.,.3276,1935.(2)Liechnitz K.,.19,1976,.159161.(3)McKee E.S.McConnaughey P.W.,.47,1986,.475-481.(4)Kitagawa T.,13-,NY,1960.(5),OH,1-.,1976.(6)Collings A.J.,.54,1982,.1763-1767.ASTM D 4913-00(2016)13(7)Saltzman B.E.,OH,5-.,1978,.S2-S39.(8)Liechnitz K.,Ecomed,Lue-beck,FRG,1983.(9)McKee E.S.McConnaughey P.W.,MI,1984.(10)Colen,F.H.,.TR-71,WV,15 1972.(11),.38,.88,.11458,8 1973.(12)Roper,P.,NIOSH ,.35,1974,.438-442.(13)Acer K.S.,7 ,Appl.Occup.Environ.Hyg.,.8,1993,.409.(14)McCammon S.,Crouse W.E.Carroll,H.B.,.43,1982,.18-25.(15)Jentzch D.Frazer,D.A.,.42,1981,.810-823.(16)Liechnitz,K.,.115,.4,1977,.ASTM D 4913-00(2016)14 59-61.(17)McConnaughey P.W.,McKee E.S.Pritts,I.M.,.46,1985,.357-362.(18),Willson Safety Products,Reading,PA,1985.ASTM International -,.,.,.-ASTM International.,.,.ASTM International,100 Barr Harbor Drive,West Conshohocken,PA 19428.610-832-9585,610-832-9555 E-mail:serviceastm.org ASTM:(www.astm.org).,222 Rosewood Drive,Danvers,MA 01923,Tel:(978)646-2600;http:/.