温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_5329_
_09
Designation:D532909Standard Test Methods forSealants and Fillers,Hot-Applied,for Joints and Cracks inAsphaltic and Portland Cement Concrete Pavements1This standard is issued under the fixed designation D5329;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 These test methods cover tests for hot-applied types ofjoint and crack sealants and fillers for portland cement concreteand asphaltic concrete pavements.There are numerous stan-dard material specifications that use these test methods.Referto the respective standard material specification of interest todetermine which of the following test methods to use.Forsample melting and concrete block preparation see theirrespective standard practices.1.2 The test methods appear in the following sections:SectionArtificial Weathering15Asphalt Compatibility14Bond,Non-Immersed9Bond,Fuel-Immersed11Bond,Water-Immersed10Cone Penetration,Non-Immersed6Cone Penetration,Fuel-Immersed7Flexibility18Flow8Resilience12Resilience,Oven-Aged13Solubility17Tensile Adhesion161.3 The values stated in SI units are to be regarded as thestandard.The values given in parentheses are provided forinformation purposes only.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2D5 Test Method for Penetration of Bituminous MaterialsD217 Test Methods for Cone Penetration of LubricatingGreaseD471 Test Method for Rubber PropertyEffect of LiquidsD1074 Test Method for Compressive Strength of Bitumi-nous MixturesD1561 Practice for Preparation of Bituminous Mixture TestSpecimens by Means of California Kneading CompactorD1985 Practice for Preparing Concrete Blocks for TestingSealants,for Joints and CracksD3381 Specification for Viscosity-Graded Asphalt Cementfor Use in Pavement ConstructionD5167 Practice for Melting of Hot-Applied Joint and CrackSealant and Filler for EvaluationD6690 Specification for Joint and Crack Sealants,HotApplied,for Concrete and Asphalt PavementsE145 Specification for Gravity-Convection and Forced-Ventilation OvensE171 Practice for Conditioning and Testing Flexible BarrierPackagingG151 Practice for Exposing Nonmetallic Materials inAccel-erated Test Devices that Use Laboratory Light SourcesG154 Practice for Operating Fluorescent Ultraviolet(UV)Lamp Apparatus for Exposure of Nonmetallic MaterialsG155 Practice for Operating Xenon Arc Light Apparatus forExposure of Non-Metallic Materials3.Significance and Use3.1 These test methods describe procedures for determiningspecification conformance for hot-applied,field-molded jointand crack sealants and fillers.4.Sample Melting4.1 See Practice D5167.5.Standard Conditions5.1 The laboratory atmospheric conditions,hereinafter re-ferred to as standard conditions,shall be in accordance withSpecification E171(23 6 2C(73.4 6 3.6F).6.Cone Penetration,Non-Immersed6.1 ScopeThis test method covers determination of conepenetration of bituminous joint and crack sealers and fillers.1These test methods are under the jurisdiction of ASTM Committee D04 onRoad and Paving Materials and are the direct responsibility of SubcommitteeD04.33 on Formed In-Place Sealants for Joints and Cracks in Pavements.Current edition approved June 1,2009.Published July 2009.Originally approvedin 1992.Last previous edition approved in 2007 as D5329 07.DOI:10.1520/D5329-09.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 6.2 Significance and UseThe cone penetration,non-immersed is a measure of consistency.Higher values indicatea softer consistency.6.3 ApparatusConduct this test using the apparatus de-scribed in Test Method D5,except as specified herein.Use apenetration cone in place of the standard penetration needle.The cone shall conform to the requirements given in TestMethods D217,except that the interior construction may bemodified as desired.The total moving weight of the cone andattachments shall be 150.0 6 0.1 g.6.4 Specimen PreparationPour a portion of the sampleprepared in accordance with Practice D5167 into one 177 mL(6 oz)tin measuring approximately 70 mm in diameter and 45mm in depth and fill flush with the rim of the tin.Allow thespecimen to cure under standard conditions as specified in itsrespective material specification.6.5 ProcedurePlace the specimen in a water