分享
ASTM_D_5075_-_01_2022.pdf
下载文档

ID:177843

大小:128.03KB

页数:8页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_5075_ _01_2022
Designation:D507501(Reapproved 2022)Standard Test Method forNicotine and 3-Ethenylpyridine in Indoor Air1This standard is issued under the fixed designation D5075;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers the sampling/analysis of nico-tine and 3-ethenylpyridine(3-EP)in indoor air.This testmethod is based upon the collection of nicotine and 3-EP byadsorption on a sorbent resin,extraction of nicotine and 3-EPfrom the sorbent resin,and determination by gas chromatog-raphy(GC)with nitrogen selective detection(1).21.2 The active samplers consist of an macroreticularpolystyrene-divinylbenzene copolymer(for example,XAD-4)sorbent tube attached to a sampling pump.Macroreticularpolystyrene-divinylbenzene copolymer is referred to“sorbentresin”throughout this method.This test method is applicable topersonal or area sampling.1.3 This test method is limited in sample duration by thecapacity of the sorbent tube for nicotine(about 300 g).Thistest method has been evaluated up to 24-h sample duration;however,samples are typically acquired for at least 1 h(sometimes only 1 h)(2).1.4 For this test method,limits of detection(LOD)andquantitation(LOQ)for nicotine at a sampling rate of 1.5 L/minare,respectively,0.11 g/m3and 0.37 g/m3for 1-h sampleduration and 0.01 g/m3and 0.05 g/m3for 8-h sampleduration.The LOD and LOQ for 3-EP at a sampling rate of 1.5L/min are,respectively,0.06 g/m3and 0.19 g/m3for 1-hsample duration and 0.01 g/m3and 0.02 g/m3for 8-h sampleduration(2).Both LOD and LOQ can be reduced by increasingthe sensitivity of the thermionic specific detector.1.5 UnitsThe values stated in SI units are to be regardedas standard.No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.Specific precautionary information is given in 13.6.1.7 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:3D1356 Terminology Relating to Sampling and Analysis ofAtmospheresD1357 Practice for Planning the Sampling of the AmbientAtmosphereD3631 Test Methods for Measuring Surface AtmosphericPressureD5337 Practice for Flow Rate Adjustment of Personal Sam-pling PumpsE260 Practice for Packed Column Gas ChromatographyE355 Practice for Gas Chromatography Terms and Relation-ships3.Terminology3.1 DefinitionsFor definitions of terms used in this testmethod,refer to Terminology D1356 and Practice E355.3.2 Definitions of Terms Specific to This Standard:3.2.1 environmental tobacco smoke(ETS)an aged,dilutecomposite of exhaled tobacco smoke(exhaled mainstreamsmoke)and smoke from tobacco products(sidestream smoke).3.2.2 nitrogen-phosphorus detector(NPD)a highly sensi-tive device selective for detection of nitrogen-and phosphorus-containing organic compounds.4.Summary of Test Method4.1 A known volume of air is drawn through a sorbentsampling tube containing resin to adsorb the nicotine and 3-EPpresent.1This test method is under the jurisdiction of ASTM Committee D22 on AirQuality and is the direct responsibility of Subcommittee D22.05 on Indoor Air.Current edition approved March 1,2022.Published April 2022.Originallyapproved in 1990.Last previous edition approved in 2017 as D5075 01(2017)1.DOI:10.1520/D5075-01R22.2The boldface numbers in parentheses refer to a list of references at the end ofthe text.3For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.14.2 The sorbent tube contents are transferred to a 2-mLautosampler vial,and the nicotine and 3-EP are desorbed withethyl acetate containing 0.01%triethylamine and a knownquantity of quinoline,the internal standard.4.3 An aliquot of the desorbed sampl

此文档下载收益归作者所有

下载文档
猜你喜欢
你可能关注的文档
收起
展开