分享
ASTM_D_4954_-_89_2017.pdf
下载文档

ID:177633

大小:80.87KB

页数:3页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_4954_ _89_2017
Designation:D495489(Reapproved 2017)Standard Test Method forDetermination of Nitrilotriacetates in Detergents1This standard is issued under the fixed designation D4954;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method describes the determination of nitrilo-triacetates(NTA)in detergents.1.2 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.For specific safetyprecautions,see 6.5.2.Summary of Test Method2.1 A known excess amount of copper nitrate solution isadded to the detergent sample under controlled pH conditions.The uncomplexed copper is back-titrated potentiometricallywith a standard NTA solution using a copper ion specificelectrode.The millimoles of NTA in the sample are equivalentto the millimoles of copper added,less the millimoles of theNTA titrant.3.Significance and Use3.1 This test method is suitable in research,development,and manufacturing control to monitor the level of NTA,asequestering agent,in powder and liquid detergents.3.2 Accurate determination of a sequestering agent is im-portant in evaluating cost and performance of detergent prod-ucts.4.Interferences4.1 The presence of substances that will make coppercomplex like citrate,formate,ethylenediaminetetraacetate,andphosphonate,will interfere positively in the determination ofNTA.5.Apparatus5.1 Volumetric Flasks,200-mL,500-mL,1000-mL.5.2 Beakers,200-mL(tall form),250-mL,1000-mL.5.3 Pipets,25-mL,100-mL.5.4 Graduated Cylinders,10-mL,25-mL.5.5 Copper Ion Electrode(Orion Model 94-29).5.6 Single Junction Reference Electrode(Orion Model 90-01),filled with Orion 90-00-01 solution.5.7 pH Combination Electrode.5.8 Burets,10-mL,25-mL,50-mL.5.9 pH Meter,with millivolt capabilities.5.10 Automatic Titratormay be substituted for 5.8 and5.9.5.11 Magnetic Stirrer/Hot Plate.5.12 Balance,with 1-mg sensitivity.6.Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests.Unless otherwise indicated,it is intended thatall reagents shall conform to specifications of the Committeeon Analytical Reagents of the American Chemical Society,where such specifications are available.2Other grades may besubstituted,provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.6.2 Disodium Ethylenediaminetetraacetate(EDTA),0.1 M.36.3 Nitric Acid,concentrated.6.4 Sodium Hydroxide,50%reagent solution.6.5 Sodium Hydroxide,20%solution.Mix 40 g of the 50%solution with 60 g of water.Cool.Wear a face shield duringmixing.6.6 Cupric Nitrate,0.1 M.Weigh(to the nearest 0.1 g)6.3g of copper metal and transfer into a 600-mLbeaker.Add about100 mL of water.Place a magnetic bar into the beaker and1This test method is under the jurisdiction of ASTM Committee D12 on Soapsand Other Detergents and is the direct responsibility of Subcommittee D12.12 onAnalysis and Specifications of Soaps,Synthetics,Detergents and their Components.Current edition approved Jan.1,2017.Published February 2017.Originallyapproved in 1989.Last previous edition approved in 2009 as D4954-89(2009).DOI:10.1520/D4954-89R17.2American Chemical Society,1155 16th St.,NW,Washington,DC 20036.3EDTA solution is available from J.T.Baker Inc.,already standardized againstNIST Reference Material Calcium Carbonate.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 place on a stirrer/hotplate.Add 30 mL of concentrated nitricacid while stirring and heat gently.Stir until the copper metaldissolves.Add more nitric acid if undissolved metal remains.After dissolution,cool and transfer quantitatively to a 1-Lvolumetric flask.Dilute to the mark and mix the solution well.6.6.1 Alternatively,weigh out(to the nearest 1 g)23 g ofreagent grade cupric nitrate,212hydrate crystals,and transferto a 600-mL beaker.Add 400 mL of water.Stir to dissolve thecrystals and add 5 mL of concentrated nitric acid.Transfer toa 1-L volumetric flask,dilute to the mark and mix well.6.7 Trisodium Nitrilotriacetate Monohydrate(NTA),0.3 M.Weigh out(to the nearest 1 g)41 g of NTA and dissolve

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开