温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_5317_
_98_2017
Designation:D531798(Reapproved 2017)Standard Test Method forDetermination of Chlorinated Organic Acid Compounds inWater by Gas Chromatography with an Electron CaptureDetector1This standard is issued under the fixed designation D5317;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers a gas chromatographic proce-dure for the quantitative determination of selected chlorinatedacids and other acidic herbicides in water.Similar chemicalsmay also be determined by this test method,but it is the usersresponsibility to verify the applicability of this test method toany compounds not listed in this scope.The acid form of thefollowing compounds were interlaboratory tested using thistest method,and the results were found acceptable:2AnalyteChemical Abstract ServicesRegistry NumberBentazon25057-89-02,4-D94-75-72,4-DB94-82-6DCPA acid metabolites2Dicamba1918-00-93,5-Dichlorobenzoic acid51-36-5Dichlorprop120-36-55-Hydroxydicamba7600-50-2Pentachlorophenol(PCP)87-86-5Picloram1918-02-12,4,5-T93-76-52,4,5-TP(Silvex)93-72-11.2 This test method may be applicable to the determinationof salts and esters of analyte compounds.The form of each acidis not distinguished by this test method.Results are calculatedand reported for each listed analyte as the total free acid.1.3 This test method has been validated in an interlaboratorytest for reagent water and finished tap water.The analyst shouldrecognize that precision and bias reported in Section 18 maynot be applicable to other waters.1.4 This test method is restricted to use by or under thesupervision of analysts experienced in the use of gas chroma-tography(GC)and in the interpretation of gas chromatograms.Each analyst must demonstrate the ability to generate accept-able results with this test method using the procedure describedin 19.3.It is the users responsibility to ensure the validity ofthis test method for waters of untested matrices.1.5 Analytes that are not separated chromatographically,that is,which have very similar retention times,cannot beindividually identified and measured in the same calibrationmixture or water sample unless an alternate technique foridentification and quantitation exists(16.6,16.7,and 16.8).1.6 When this test method is used to analyze unfamiliarsamples for any or all of the analytes given in 1.1,analyteidentifications must be confirmed by at least one additionalqualitative technique.1.7 The values stated in SI units are to be regarded asstandard.The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.8 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.For specific warning statements,see Sections 6,8,9,and 10.1.9 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:3D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on Water1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.06 on Methods forAnalysis forOrganic Substances in Water.Current edition approved Dec.15,2017.Published January 2018.Originallyapproved in 1992.Last previous edition approved in 2011 as D5317 93(2011).DOI:10.1520/D5317-98R17.2DCPA monoacid and diacid metabolites are included in the scope of this testmethod;DCPA diacid metabolite is used for validation studies.3For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 D3370 Practices for Sampling Water from Closed ConduitsD3856 Guide for Management Syst