分享
ASTM_D_4906_-_95_2012.pdf
下载文档

ID:176362

大小:59.22KB

页数:2页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_4906_ _95_2012
Designation:D490695(Reapproved 2012)Standard Test Method forTotal Solids and Ash Content in Leather Finishing Materials1This standard is issued under the fixed designation D4906;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers the total solids and ash contentof finishing materials.1.2 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Significance and Use2.1 This test method is intended for use in determining thetotal solids content and the ash content of a finishing materialbefore its use on any leather.3.Apparatus3.1 Two Tared Platinum Dishes.3.2 Drying Oven,that operates at 43C 6 3C and 93C 63C.3.3 Desiccator,with calcium chloride or other desiccant.3.4 Muffle Furnace,capable of maintaining temperatures of(600C 6 25C).4.Sampling4.1 One 5-g and one 10-g sample of the finishing materialshall be weighed with accuracy to within 0.001 g.5.Procedure5.1 Total Solids:5.1.1 Place the samples,which have been weighed inplatinum dishes,in the oven for 16 h at 43C followed by 2 hat 93C.(If two ovens at different temperatures are notavailable,increase the temperature in the first oven for the 2-hheating.)5.1.2 Remove the dishes from the oven,place them in adesiccator for 1 h to cool to room temperature and weigh.Return the dishes to the oven for 1 h at 93C and,after coolingin a desiccator for 1 h,weigh again.5.1.3 If the weight loss in the 1-h drying period did notchange the total solids percentage more than 0.1%,report theresults.If greater than 0.1%loss was obtained from the last1-h drying period,then repeat the drying until the change isless than 0.1%.5.2 Ash:5.2.1 Place each platinum dish,containing the residue fromthe total solids determination,in a muffle furnace at 600C 625C for 2 h.5.2.2 If difficulty is encountered in completely burning offthe carbon,leach the residue with hot water(filtering throughashless filter paper)and further ignite this residue in the mufflefurnace.5.2.3 To the dish containing the cooled ash,add the filtrate;evaporate to dryness and heat for 30 min at 600C 6 25C.Theproduct shall then be cooled in a dessicator and weighed.6.Calculation6.1 The percent total solids of the finishing material shall becalculated as follows:Total solids,percent5AB3100(1)where:A=final weight of solid matter after drying,andB=the original weight of the sample.6.2 The percent ash content of the finishing material shall becalculated as follows:Ash content,percent5CB3100(2)where:C=final weight of ash,andB=the original weight of the sample.1This test method is under the jurisdiction of ASTM Committee D31 on Leatherand is the direct responsibility of Subcommittee D31.06 on Chemical Analysis andhas been produced in cooperation with the American Leather Chemists Association.(Method K 1-1956).Current edition approved April 1,2012.Published April 2012.Originallyapproved in 1989.Last previous edition approved in 2006 as D490695(2006).DOI:10.1520/D4906-95R12.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 7.Report7.1 The total solids in the finishing material is the average ofthe duplicate results and shall be reported in percent.7.2 The ash content of the finishing material,likewise,is theaverage of the duplicate results and shall also be reported inpercent.8.Precision and Bias8.1 No justifiable statement can be made on the precisionand bias of this test method because the original interlaboratorytest data is no longer available.8.2 However,the user is cautioned to verify by the use ofreference materials,if available,that the precision and bias ofthis test method is adequate for the contemplated use.9.Keywords9.1 ash;finishes;finishing materials;total solidsASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard.Users of this standard are expressly advised that determination of the validity of any such patent rights,and the riskof infringement of such rights,are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised,either reapproved or withdrawn.Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters.Your comments will receive careful consid

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开