分享
ASTM_D_5438_-_17.pdf
下载文档

ID:175867

大小:230.66KB

页数:8页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_5438_ _17
Designation:D543817Standard Practice forCollection of Floor Dust for Chemical Analysis1This standard is issued under the fixed designation D5438;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice covers a procedure for the collection of asample of dust from carpets and bare floors that can beanalyzed for lead,pesticides,or other chemical compounds andelements.1.2 This practice is applicable to a variety of carpeted andbare floor surfaces.It has been tested for level loop and plushpile carpets and bare wood floors,specifically.1.3 This practice is not intended for the collection andevaluation of dust for the presence of asbestos fibers.1.4 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2D422 Test Method for Particle-Size Analysis of Soils(With-drawn 2016)3D1356 Terminology Relating to Sampling and Analysis ofAtmospheresE1 Specification for ASTM Liquid-in-Glass ThermometersE337 Test Method for Measuring Humidity with a Psy-chrometer(the Measurement of Wet-and Dry-Bulb Tem-peratures)E1137/E1137M Specification for Industrial Platinum Resis-tance ThermometersE2251 Specification for Liquid-in-Glass ASTM Thermom-eters with Low-Hazard Precision LiquidsF608 Test Method for Evaluation of Carpet Embedded DirtRemovalEffectivenessofHousehold/CommercialVacuum Cleaners3.Terminology3.1 DefinitionsFor definitions of terms used in thispractice,refer to Terminology D1356.3.1.1 carpet-embedded dustsoil and other particulatematter,approximately 5-m equivalent aerodynamic diameterand larger,embedded in carpet pile and normally removable byhousehold vacuum cleaners.3.1.2 surface dustsoil and other particulate matter,ap-proximately 5-m equivalent aerodynamic diameter and larger,adhering to floor surfaces and normally removable by house-hold vacuum cleaners.4.Summary of Practice4.1 The sampling method described in this practice is takenfrom work published in Roberts et al.(1-3),4and Stamper et al.(4).4.2 Particulate matter is withdrawn from the carpet or barefloor by means of vacuum-induced suction which drawsthrough a sampling nozzle at a specific velocity and flow rate,and the particles are separated mechanically by a cyclone.Thecyclone is designed to efficiently separate and collect particlesapproximately 5-m mean aerodynamic diameter and larger.However,much smaller particles are also collected at unknownefficiencies.The sampling system allows for height,air flow,and suction adjustments to reproduce systematically a specificair velocity for the removal of particulate matter from carpetedand bare floor surfaces,so that these sampling conditions canbe repeated.NOTE1Side-by-side comparison of the HVS3 and a conventionalupright vacuum cleaner revealed that both collected particles down to atleast 0.2 m and that the HVS3 was more efficient at collecting particlessmaller than 20 m than conventional vacuum cleaners(5).If desired,afine-particle filter may be added downstream of the cyclone to collect99.9%of particles above 0.2 m aerodynamic mean diameter.4.3 The particulate matter in the air stream is collected in acatch bottle attached to the bottom of the collection cyclone.1This practice is under the jurisdiction ofASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.05 on Indoor Air.Current edition approved March 1,2017.Published March 2017.Originallyapproved in 1993.Last previous edition approved in 2011 as D5438 11.DOI:10.1520/D5438-17.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4The boldface numbers in parentheses refer to the list of references at the end ofthis standard.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 This catch bottle shall be capped for storage of the sample andtransported to the laboratory

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开