分享
ASTM_D_6246_-_08_2013e1.pdf
下载文档

ID:175560

大小:139.49KB

页数:8页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_6246_ _08_2013e1
Designation:D624608(Reapproved 2013)1Standard Practice forEvaluating the Performance of Diffusive Samplers1This standard is issued under the fixed designation D6246;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1NOTEThe References Section was editorially corrected in July 2015.1.Scope1.1 This practice covers the evaluation of the performanceof diffusive samplers of gases and vapors for use over samplingperiods from 4 to 12 h and for wind speeds less than 0.5 m/s.Such sampling periods and wind speeds are the most commonin the indoor workplace setting.This practice does not apply tostatic or area sampling in wind speeds less than 0.1 m/s,whendiffusion outside the sampler may dominate needed convectionfrom the ambient air to the vicinity of the sampler.Given asuitable exposure chamber,the practice can be extended tocover sampler use for other sampling periods and conditions.The aim is to provide a concise set of experiments forclassifying samplers primarily in accordance with a singlesampler accuracy figure.Accuracy is defined(3.2.1)in thisstandard so as to take into account both imprecision anduncorrected bias.Accuracy estimates refer to conditions ofsampler use which are normally expected in a workplacesetting.These conditions may be characterized by thetemperature,atmospheric pressure,humidity,and ambientwind speed,none of which may be constant or accuratelyknown when the sampler is used in the field.Futhermore,theaccuracy accounts for the effects of diffusive loss of analyte onthe estimation of time-weighted averages of concentrationswhich may not be constant in time.Aside from accuracy,thesamplers are tested for compliance with the manufacturersstated limits on capacity,possibly in the presence of interferingcompounds.1.2 This practice is an extension of previous research ondiffusive samplers(1-14)2as well as Practices D4597,D4598,D4599,and MDHS 27.An essential advance here is theestimation of sampler accuracy under actual conditions of use.Futhermore,the costs of sampler evaluation are reduced.1.3 Knowledge gained from similar analytes expedites sam-pler evaluation.For example,interpolation of data character-izing the sampling of analytes at separated points of ahomologous series of compounds is recommended.At presentthe procedure of(9)is suggested.Following evaluation of asampler in use at a single homologous series member accord-ing to the present practice,higher molecular weight memberswould receive partial validations considering sampling rate,capacity,analytical recovery,and interferences.The test fordiffusive analyte loss can be omitted if the effect is foundnegligible for a given sampler or analyte series.1.4 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:3D1356 Terminology Relating to Sampling and Analysis ofAtmospheresD4597 Practice for Sampling Workplace Atmospheres toCollect Gases or Vapors with Solid Sorbent DiffusiveSamplersD4598 Practice for Sampling Workplace Atmospheres toCollect Gases or Vapors with Liquid Sorbent DiffusionalSamplers(Withdrawn 1995)4D4599 Practice for Measuring the Concentration of ToxicGases or Vapors Using Length-of-Stain Dosimeters2.2 International Standards:CEN EN 838 European Standard,Workplace atmospheres-Diffusive samplers for the determination of gases orvapours-Requirements and test methods51This practice is under the jurisdiction ofASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.04 on Workplace Air Quality.Current edition approved April 1,2013.Published April 2013.Originallyapproved in 1998.Last previous edition approved in 2008 as D6246 08.DOI:10.1520/D6246-08R13E01.2The boldface numbers in parentheses refer to the list of references at the end ofthis standard.3For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.4The last approved version of this historical standard is referenced onwww.astm.org.5Available from CEN Central Secretariat,rue de Stassart 36,B-1050 Brussels,Belgium.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 MDHS 27 Protocol for assessing the performance of adiffusive sampler,Health and Safety Laboratory,UnitedKingdom6MDHS 80 Volatile organ

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开