温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_6061_
_01_2018e1
Designation:D606101(Reapproved 2018)1Standard Practice forEvaluating the Performance of Respirable AerosolSamplers1This standard is issued under the fixed designation D6061;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1NOTEReapproved with editorial changes in December 2018.1.Scope1.1 This practice covers the evaluation of the performanceof personal samplers of non-fibrous respirable aerosol.Thesamplers are assessed relative to a specific respirable samplingconvention.The convention is one of several that identifyspecific particle size fractions for assessing health effects ofairborne particles.When a health effects assessment has beenbased on a specific convention it is appropriate to use that sameconvention for setting permissible exposure limits in theworkplace and ambient environment and for monitoring com-pliance.The conventions,which define inhalable,thoracic,andrespirable aerosol sampler ideals,have now been adopted bythe International Standards Organization(ISO 7708),the Co-mit Europen de Normalisation(CEN Standard EN 481),andthe American Conference of Governmental Industrial Hygien-ists(ACGIH,Ref(1),2developed(2)in part from health-effects studies reviewed in Ref(3)and in part as a compromisebetween definitions proposed in Refs(3,4).1.2 This practice is complementary to Test Method D4532,which specifies a particular instrument,the 10-mm cyclone.3The sampler evaluation procedures presented in this practicehave been applied in the testing of the 10-mm cyclone as wellas the Higgins-Dewell cyclone.3,4Details on the evaluationhave been published(5-7)and can be incorporated intorevisions of Test Method D4532.1.3 A central aim of this practice is to provide informationrequired for characterizing the uncertainty of concentrationestimates from samples taken by candidate samplers.For thispurpose,sampling accuracy data from the performance testsgiven here can be combined with information as to analyticaland sampling pump uncertainty obtained externally.The prac-tice applies principles of ISO GUM,expanded to coversituations common in occupational hygiene measurement,where the measurand varies markedly in both time and space.A general approach(8)for dealing with this situation relates tothe theory of tolerance intervals and may be summarized asfollows:Sampling/analytical methods undergo extensiveevaluations and are subsequently applied without re-evaluationat each measurement,while taking precautions(for example,through a quality assurance program)that the method remainsstable.Measurement uncertainty is then characterized byspecifying the evaluation confidence(for example,95%)thatconfidence intervals determined by measurements bracketmeasurand values at better than a given rate(for example,95%).Moreover,the systematic difference between candidateand idealized aerosol samplers can be expressed as a relativebias,which has proven to be a useful concept and is includedin the specification of accuracy(3.2.13,3.2.13.1,3.2.13.3).1.4 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.1This practice is under the jurisdiction ofASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.04 on Workplace Air Quality.Current edition approved Dec.1,2018.Published January 2019.Originallyapproved in 1996.Last previous edition approved in 2012 as D6061 01(2012)1.DOI:10.1520/D6061-01R18E01.2The boldface numbers in parentheses refer to a list of references at the end ofthis practice.3If you are aware of alternative suppliers,please provide this information toASTM Headquarters.Your comments will receive careful consideration at a meetingof the responsible technical committee,1which you may attend.4The sole source of supply of the Higgins-Dewell cyclone known to thecommittee at this time is BGI Inc.,58 Guinan Street,Waltham,MA 02154.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principl