分享
ASTM_D_5713_-_14_2018e1.pdf
下载文档

ID:174863

大小:118.61KB

页数:4页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_5713_ _14_2018e1
Designation:D571314(Reapproved 2018)1Standard Test Method forAnalysis of High Purity Benzene for Cyclohexane Feedstockby Capillary Gas Chromatography1This standard is issued under the fixed designation D5713;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1NOTEEditorial corrections made in Footnote 1 and 8.1 in June 2018.1.Scope1.1 This test method covers the determination of specificimpurities in,and the purity of benzene for cyclohexanefeedstock by gas chromatography.1.2 This test method has been found applicable to benzenein the range from 99 to 100%purity and to impurities atconcentrations of 2 to 10 000 mg/kg.1.3 In determining the conformance of the test results usingthis method to applicable specifications,results shall berounded off in accordance with the rounding-off method ofPractice E29.1.4 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.For specific hazard statements,see 7.2 and Section 8.1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D3437 Practice for Sampling and Handling Liquid CyclicProductsD4790 Terminology of Aromatic Hydrocarbons and RelatedChemicalsD6809 Guide for Quality Control and Quality AssuranceProcedures for Aromatic Hydrocarbons and Related Ma-terialsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE260 Practice for Packed Column Gas ChromatographyE355 Practice for Gas Chromatography Terms and Relation-shipsE1510 Practice for Installing Fused Silica Open TubularCapillary Columns in Gas Chromatographs2.2 Other Document:OSHA Regulations,29 CFR paragraphs 1910.1000 and1910.120033.Terminology3.1 Definitions:3.1.1 See Terminology D4790 for definition of terms used inthis test method.4.Summary of Test Method4.1 In this test method,the chromatogram peak area for eachimpurity is compared to the peak area of the internal standard(n-octane or other suitable known)added to the sample.Fromthe response factor of toluene relative to that of the internalstandard,and using a response factor of 1.00 for nonaromaticimpurities and the amount of internal standard added,theconcentrations of the impurities are calculated.The benzenecontent is obtained by subtracting the total amount of allimpurities from 100.00.5.Significance and Use5.1 This test method is useful for benzene purity on thebasis of impurities normally present in benzene and may beused for final product inspections and process control.1This test method is under the jurisdiction of ASTM Committee D16 onAromatic,Industrial,Specialty and Related Chemicals and is the direct responsi-bility of Subcommittee D16.01 on Benzene,Toluene,Xylenes,Cyclohexane andTheir Derivatives.Current edition approved June 1,2018.Published June 2018.Originallyapproved in 1995.Last previous edition approved in 2014 as D5713 14.DOI:10.1520/D5713-14R18E01.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from U.S.Government Printing Office Superintendent of Documents,732 N.Capitol St.,NW,Mail Stop:SDE,Washington,DC 20401,http:/www.access.gpo.gov.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 5.2 This test method will detect the following impurities:toluene,methylcyclopentane,n-hexane,2-methylhexane,cyclohexane,cyclopentane,2-methylpentane,2,3-dimethylpentane,3-methylhexane,n-heptane,methylcyclohexane,ethylcyclopentane,2,4-dimethylhexane,trimethylpentane,and others where specific impurity standardsare available.Absolute purity cannot be accurately determinedif unknown impurities are present.6.Apparatus6.1 Gas ChromatographAny gas chromatograph havin

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开