分享
ASTM_D_6301_-_21.pdf
下载文档

ID:174792

大小:118.29KB

页数:5页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_6301_ _21
Designation:D630121Standard Practice forCollection of On-Line Composite Samples of SuspendedSolids and Ionic Solids in Process Water1This standard is issued under the fixed designation D6301;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice is applicable for sampling condensedsteam or water,such as boiler feedwater,for the collection ofsuspended solids and(optional)ionic solids using a 0.45-mmembrane filter(suspended solids)and ion exchange media(ionic solids).As the major suspended component found inmost boiler feedwaters is some form of corrosion product fromthe preboiler system,the device used for this practice iscommonly called a corrosion product sampler.1.2 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D1066 Practice for Sampling SteamD1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD1971 Practices for Digestion of Water Samples for Deter-mination of Metals by FlameAtomicAbsorption,GraphiteFurnaceAtomicAbsorption,PlasmaEmissionSpectroscopy,or Plasma Mass SpectrometryD2332 Practice for Analysis of Water-Formed Deposits byWavelength-Dispersive X-Ray FluorescenceD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3370 Practices for Sampling Water from Flowing ProcessStreamsD3864 Guide for On-Line Monitoring Systems for WaterAnalysis3.Terminology3.1 Definitions:3.1.1 For definitions of terms used in this standard,refer toTerminology D1129.3.2 Definitions of Terms Specific to This Standard:3.2.1 corrosion product sampler,na device used to collectintegrated samples of suspended solids and(as an option)ionicsolids.3.2.1.1 DiscussionIt consists of a flow totalizer that accu-rately measures the amount of sample passing through thedevice and a 0.45-m pore size membrane filter.Adding asecond filter for ion exchange resin impregnated membranesallows for collecting ionic solids.3.2.2 ionic solids,nincludes all matter that will passthrough a 0.45-m pore size filter and may be captured onanion,or cation ion exchange membranes,or both.3.2.3 suspended solids,nincludes all matter that is re-moved by a 0.45-m pore size filter.4.Summary of Practice4.1 A typical sampling apparatus,or corrosion productsampler,is used to obtain integrated,representative samples ofsuspended solids and ionic solids using a 0.45-m membranefilter and ion exchange membranes.The sampling is accom-plished at system operating pressure or after pressurereduction,and sample temperature of 50C.The practiceutilizes a modified stainless steel high pressure filter housing toaccommodate a 47-mm diameter filter(for suspended solids)and if desired,ion exchange membranes(for ionic solids).Thesample collection system(corrosion product sampler)is de-signed and operated specifically for quantitative collection of1This practice is under the jurisdiction of ASTM Committee D19 on Water andis the direct responsibility of Subcommittee D19.03 on Sampling Water andWater-Formed Deposits,Analysis of Water for Power Generation and Process Use,On-Line Water Analysis,and Surveillance of Water.Current edition approved Dec.1,2021.Published December 2021.Originallyapproved in 1998.Last previous edition approved in 2013 as D6301 13.DOI:10.1520/D6301-21.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1?FIG.1 Simplified Flow Diagram for Corrosion Product SamplerD6301 212?suspended solids and ionic solids.An important feature o

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开