分享
ASTM_D_6505_-_00_2022.pdf
下载文档

ID:174493

大小:58.93KB

页数:2页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_6505_ _00_2022
Designation:D650500(Reapproved 2022)Standard Test Method forAssay of normal-Propyl Bromide Content1This standard is issued under the fixed designation D6505;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method provides a basis for the determinationof the normal-propyl bromide(weight%)in the presence ofstabilizers and impurities,in virgin or reclaimed normal-propylbromide(nPB).The application range is from 50 wt%to 100wt%.1.2 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Summary of Test Method2.1 This analytical test method describes the determinationof the assay of n-propyl bromide by gas chromatography usingan internal standard.The results are reported in weight percent.3.Significance and Use3.1 This test method provides an analysis in weight percentof the normal-propyl bromide concentration of virgin,formulated,or reclaimed normal-propyl bromide:compoundsthat co-elute with normal-propyl bromide or normal-heptane(internal standard)may interfere with this test method.4.Apparatus4.1 Gas ChromatographHewlett Packard 5890 Series IIequipped with a split/splitless injector,a flame ionizationdetector,and an autosampler,HP,or equivalent,if available.4.2 Column30 m by 0.25 mm,1.0 m film thicknessAllTech AT-5,or equivalent,capillary column.4.3 Syringe5 L or 10 L GC autosampler syringe.4.4 Data Acquisition and Analysis DeviceVAX MULTI-CHROM or equivalent chromatography data collection andprocessing system,or integrator.4.5 Crimp Top VialsHewlett Packard 2 mL glass crimptop vials with TFE-fluorocarbon-lined silicone septa or equiva-lent.4.6 Volumetric Pipet25 mL.4.7 Glass Vials32 mLglass vials(25 mm by 95 mm),withTFE-fluorocarbon-lined screw caps.4.8 Transfer PipetsBorosilicate glass transfer pipets.4.9 Precision Balance,accurate to 0.1 mg.5.Required Chemicals5.1 n-Propyl Bromide(1-Bromopropane),99+%,AldrichChemical Company5.2 n-Heptane(internal standard),Reagent Grade,99.5+%,J.T.Baker(or equivalent)5.3 Methylene Chloride,99+%,Aldrich Chemical Com-pany(or equivalent)6.Suggested Analysis Conditions6.1 Chromatographic Conditions:Injector150 CDetector temperature250 CFID detector rangemost sensitive settingTemperatureprogram30 C for 10 min30 C to 250 C at 15 C minhold at 250 C for 10 minCarrier gasHe(or N2)at 1 mL/minsplit flow:25 mL/mincolumn head pressure:7.5 psiMake-up gasHe(or N2)at 30 mL/minInjection volume0.5 L7.Analytical Procedure7.1 Internal Standard Calibration MixtureCarefullyweigh about 0.25 g of n-heptane internal standard and about0.5 g of n-propyl bromide into a 32 mL glass vial.Record theactual weights for each.Pipet 25 mLof methylene chloride intothis vial and cap immediately.Mix well and then transferapproximately 1 mL of this standard solution into an autosam-pler vial.Cap the vial and analyze in accordance with theconditions specified in the chromatographic conditions section.1This test method is under the jurisdiction of ASTM Committee D26 onHalogenated Organic Solvents and Fire Extinguishing Agents and is the directresponsibility of Subcommittee D26.04 on Test Methods.Current edition approved May 1,2022.Published May 2022.Originallyapproved in 2000.Last previous edition approved in 2017 as D650500(2017).DOI:10.1520/D6505-00R22.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1Inject this standard at least three times and calibrate an internalstandard method in the data system using the results from thestandard analyses.7.2 Preparation of Samples for AnalysisWeigh about 0.25g of n-heptane and about 0.5 g of sample into a 32 mL glassvial.Record the actual weights for each.Pipet 25 mL ofmethylene chloride into this vial and cap immediately.Mixwell and transfer approximately 1 mL of this solution to anautosampler vial.Cap the vial and analyze in accordance withthe conditions specified in the chromatographic conditionssection.The following table shows components of interest,their absolute retention time(ART)in minutes,their relativeretention time(RRT)in relation to n-heptane,the internalstandard,as well as their relative response factor(RRf).ComponentARTRRTRRfn-propyl bromide13.300.830.3495n-heptane(internal

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开