分享
ASTM_D_6096_-_21.pdf
下载文档

ID:174238

大小:81.24KB

页数:3页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_6096_ _21
Designation:D609621Standard Specification forPoly(Vinyl Chloride)Insulation for Wire and Cable,90 COperation1This standard is issued under the fixed designation D6096;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope*1.1 This specification covers a thermoplastic insulation ofpoly(vinyl chloride)or the copolymer of vinyl chloride andvinyl acetate.This insulation is recommended for use atconductor temperatures not in excess of 90 C.1.2 Depending on the thickness of the insulation,the maxi-mum voltage used,and whether the location is wet or dry,thisinsulation is acceptable for use in 300 V(dry)and 600 V(wetor dry)power and control circuits.1.3 This insulation has potential low-temperature installa-tion limitations.Consult the manufacturer for specific recom-mendations for installation.1.4 In many instances,the insulation material cannot betested unless it has been formed around a conductor or cable.Therefore,tests are done on insulated wire or cable in thisspecification solely to determine the relevant property of theinsulation material and not to test the conductor or completedcable.1.5 The values stated in inch-pound units are to be regardedas standard.The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5.1 In some cases(including the title),temperatures aredescribed in degrees Celsius only.1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D1711 Terminology Relating to Electrical InsulationD2633 Test Methods for Thermoplastic Insulations andJackets for Wire and Cable3.Terminology3.1 Definitions:3.1.1 For definitions of terms used in this specification,referto Terminology D1711.3.2 Definitions of Terms Specific to This Standard:3.2.1 aging(act of),nexposure of materials to air or oil ata temperature and for an interval of time as required in Table1.4.Physical Properties4.1 The insulation shall conform to the requirements forphysical properties prescribed in Table 1.(See Table 2 foroptional oil resistance requirements.)1This specification is under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and is the direct responsibility ofSubcommittee D09.07 on Electrical Insulating Materials.Current edition approved Jan.1,2021.Published February 2021.Originallyapproved in 1997.Last previous edition approved in 2016 as D6096 11(2016).DOI:10.1520/D6096-21.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.5.Electrical Requirements5.1 Perform the ac voltage,insulation resistance,and dcvoltage tests in that order when any of these tests are required.The sequence for other testing is not specified.5.2 AC Voltage TestTest the insulated conductor at the acwithstand voltage as specified in Table 3.Unless otherwisespecified,omit this test if the dc withstand voltage testdescribed in 5.4 is performed.5.2.1 For cables or conditions of service where mechanicalstresses govern,such as in submarine cables or long verticalrisers,it is possible that the minimum conductor sizes in Table3 are not strong enough.5.2.2 The thicknesses given in Table 3 apply to aerial cablesand to single conductors installed in conduits above ground andto the individual conductors of all multiple-conductor cableshaving a common jacket,metallic sheath,or protective cover-ing over the assembly,excerpt as shown in 5.2.2.1.5.2.2.1 For single-conductor cables for installation in under-ground ducts or direct earth burial and for all submarine cables,add 15 mil(0.38 mm)to the insulation thicknesses given inTable 3,when such cables do not have a thermoplastic jacketor metallic sheath over the assembly.5.2.3 Where the thickness of the insulation is increased formechanical reasons or for special service conditions,determinethe te

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开