分享
ASTM_D_6348_-_12e1.pdf
下载文档

ID:174102

大小:234.88KB

页数:16页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_6348_ _12e1
Designation:D6348121Standard Test Method forDetermination of Gaseous Compounds by Extractive DirectInterface Fourier Transform Infrared(FTIR)Spectroscopy1This standard is issued under the fixed designation D6348;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1NOTEEditorial corrections were made to A2.3.2.3 in August 2014.INTRODUCTIONThis extractive FTIR based field test method is used to quantify gas phase concentrations ofmultiple target analytes from stationary source effluent.Because an FTIR analyzer is potentiallycapable of analyzing hundreds of compounds,this test method is not analyte or source specific.Theanalytes,detection levels,and data quality objectives are expected to change for any particular testingsituation.It is the responsibility of the tester to define the target analytes,the associated detectionlimits for those analytes in the particular source effluent,and the required data quality objectives foreach specific test program.Provisions are included in this test method that require the tester todetermine critical sampling system and instrument operational parameters,and for the conduct ofQA/QC procedures.Testers following this test method will generate data that will allow anindependent observer to verify the valid collection,identification,and quantification of the subjecttarget analytes.1.Scope1.1 This field test method employs an extractive samplingsystem to direct stationary source effluent to an FTIR spec-trometer for the identification and quantification of gaseouscompounds.Concentration results are provided.This testmethod is potentially applicable for the determination ofcompounds that(1)have sufficient vapor pressure to betransported to the FTIR spectrometer and(2)absorb a sufficientamount of infrared radiation to be detected.1.2 This field test method provides near real time analysis ofextracted gas samples from stationary sources.Gas streamswith high moisture content may require conditioning to mini-mize the excessive spectral absorption features imposed bywater vapor.1.3 This field test method requires the preparation of asource specific field test plan.The test plan must include thefollowing:(1)the identification of the specific target analytes(2)the known analytical interferents specific to the test facilitysource effluent(3)the test data quality necessary to meet thespecific test requirements and(4)the results obtained from thelaboratory testing(see Annex A1 for test plan requirements).1.4 The FTIR instrument range should be sufficient tomeasure from high ppm(v)to ppb(v)and may be extended tohigher or lower concentrations using any or all of the followingprocedures:1.4.1 The gas absorption cell path length may be eitherincreased or decreased,1.4.2 The sample conditioning system may be modified toreduce the water vapor,CO2,and other interfering compoundsto levels that allow for quantification of the targetcompound(s),and1.4.3 The analytical algorithm may be modified such thatinterfering absorbance bands are minimized or stronger/weakerabsorbance bands are employed for the target analytes.1.5 The practical minimum detectable concentration isinstrument,compound,and interference specific(see AnnexA2 for procedures to estimate the achievable minimum detect-able concentrations(MDCs).The actual sensitivity of theFTIR measurement system for the individual target analytesdepends upon the following:1.5.1 The specific infrared absorptivity(signal)and wave-length analysis region for each target analyte,1.5.2 The amount of instrument noise(see Annex A6),and1.5.3 The concentration of interfering compounds in thesample gas(in particular,percent moisture and CO2),and the1This test method is under the jurisdiction of Committee D22 on Air Quality andis the direct responsibility of Subcommittee D22.03 on Ambient Atmospheres andSource Emissions.Current edition approved Feb.1,2012.Published February 2012.Originallyapproved in 1998.Last previous edition approved in 2010 as D6348 03(2010).DOI:10.1520/D6348-12E01.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 amount of spectral overlap imparted by these compounds in thewavelength region(s)used for the quantification of the targetanalytes.1.5.4 Any sampling system interferences such as adsorptionor outgassing.1.6 Practices E168 and E1252 are suggested for additionalreading.1.7 This standard does not purport to address all of thesafety concerns associated with its use.It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and to determine the applicability of regula-tory limitations prior to use.Additional safety precautions aredescribed in Section 9.2.Referenced Documents2.1 ASTM Standards:2D1356 T

此文档下载收益归作者所有

下载文档
猜你喜欢
你可能关注的文档
收起
展开