温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_5888_
_19
Designation:D588819Standard Guide forStorage and Handling of Geosynthetic Clay Liners1This standard is issued under the fixed designation D5888;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This guide covers guidelines for the proper storage andhandling of geosynthetic clay liners received at the job site bythe end user.1.2 This guide contains general guidelines and is not in-tended to replace project-specific requirements as found in thecontract drawings or specifications.In the event of a conflict,the requirements of the project specifications will supersede therequirements of this guide.1.3 The values given in SI units are to be regarded as thestandard.The inch-pound units given in parentheses are forinformation only.1.4 This guide offers an organized collection of informationor a series of options and does not recommend a specific courseof action.This document cannot replace education or experi-ence and should be used in conjunction with professionaljudgement.Not all aspects of this guide may be applicable inall circumstances.This ASTM standard is not intended torepresent or replace the standard of care by which the adequacyof a given professional service must be judged,nor should thisdocument be applied without consideration of a projects manyunique aspects.The word“standard”in the title of thisdocument means only that the document has been approvedthrough the ASTM consensus process.1.5 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D4439 Terminology for Geosynthetics3.Terminology3.1 Definitions:3.1.1 core pipe,na rigid pipe or rod inserted through thecore of a GCLroll.Each end of the pipe is connected to a chainor lifting strap which attaches to equipment for GCLunloading,on-site handling,and installation.3.1.2 geosynthetic clay liner(GCL),na manufacturedhydraulic barrier consisting of clay bonded to a layer or layersof geosynthetics.3.1.3 spreader bar,na steel beam used in conjunction withthe core pipe that prevents the lifting chains or straps fromchafing against the ends of the GCL roll.3.1.4 stinger,na rigid pipe or rod with one end directlyconnected to a forklift or other equipment.The opposite end ofthe stinger can then be inserted through the GCL roll core suchthat the equipment is able to unload,handle,or install the GCL.3.1.5 For definitions of other geosynthetic terms used in thisguide,refer to Terminology D4439.4.Significance and Use4.1 For optimum performance,GCLs must be stored andhandled prior to their installation in a manner that does notimpact their hydraulic or physical properties,or both.Adher-ence to these storage and handling guidelines will help toensure that acceptable GCL performance will be achieved.5.Procedure5.1 Receiving and Handling GCL at the Job Site:5.1.1 The GCLs are packaged in individual rolls and aretypically delivered to the job site in trucks.Each roll isindividually wrapped and labeled by the GCL manufacturer.Prior to unloading the rolls,make a visual examination of theshipment in order to identify any damage that may have1This guide is under the jurisdiction ofASTM Committee D35 on Geosyntheticsand is the direct responsibility of Subcommittee D35.04 on Geosynthetic ClayLiners.Current edition approved May 1,2019.Published May 2019.Originallyapproved in 1995.Last previous edition approved in 2016 as D5888 06(2016).DOI:10.1520/D5888-19.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 occurred in transit to the site.Record and report any immedi-ately visible or suspected damage to the GCLrolls immediatelyto the GCLcarrie