温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_7883_
_20
Designation:D788320Standard Test Method forDetermination of 4-Carboxybenzaldehyde and p-Toluic Acidin Purified Terephthalic Acid by Weak Anion Exchange HighPerformance Liquid Chromatography1This standard is issued under the fixed designation D7883;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope*1.1 This test method2covers the determination of the4-Carboxybenzaldehyde(4-CBA)and p-Toluic acid(p-TOL)in purified terephthalic acid(PTA)by weak anion exchangehigh performance liquid chromatography(HPLC).Thismethod is applicable for 4-CBA from 2 to 500 mg/kg and forp-TOL from 10 to 500 mg/kg,respectively.1.2 In determining the conformance of the test results usingthis method to applicable specification,results shall be roundedoff in accordance with the rounding-off method of PracticeE29.1.3 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:3D1193 Specification for Reagent WaterD6809 Guide for Quality Control and Quality AssuranceProcedures for Aromatic Hydrocarbons and Related Ma-terialsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE682 Practice for Liquid Chromatography Terms and Rela-tionshipsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 ISO Document:4EN ISO 8213 Chemical products for industrial useSampling techniquesSolid chemical products in theform of particles varying from powders to coarse lumps2.3 Other Document:5OSHA Regulations,29 CFR paragraphs 1910.1000 and1910.12003.Summary of Test Method3.1 Weak Anion Exchange HPLC MethodPTA sample isdissolved in ammonium hydroxide solution.After pHadjustment,a fixed volume of this solution is injected into ahigh performance liquid chromatograph equipped with a UVdetector.An anion-exchange column is used to separate theimpurities 4-CBAand p-TOL from PTA.The external standardcalibration is used for quantification.1This test method is under the jurisdiction of ASTM Committee D16 onAromatic,Industrial,Specialty and Related Chemicals and is the direct responsi-bility of Subcommittee D16.02 on Oxygenated Aromatics.Current edition approved Oct.1,2020.Published December 2020.Originallyapproved in 2013.Last previous edition approved in 2019 as D7883 19.DOI:10.1520/D7883-20.2This standard is based on SH/T 1612.7-1995 Purified terephthalic acid forindustrial usedetermination of p-Toluic Acid,4-Carboxybenzaldehyde-HPLC,copyright SINOPEC,22 Chaoyangmen North Street,Chaoyang District,Beijing,China 100728.A copy of SH/T 1612.7-1995 may be obtained from ChinaPetrochemical Press,www.sinopec-.3For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.4Available from American National Standards Institute(ANSI),25 W.43rd St.,4th Floor,New York,NY 10036,http:/www.ansi.org.5Available from U.S.Government Printing Office Superintendent of Documents,732 N.Capitol St.,NW,Mail Stop:SDE,Washington,DC 20401,http:/www.access.gpo.gov.*A Summary of Changes section appears at the end of this standardCopyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.14.Significance and Use4.1 The presence of 4-CBA and p-TOL in PTA used for theproduction of polyester is undesirable because they can slowdown the polymerization process,and 4-CBAis also impartingcoloration to the polymer due to thermal instability.4.2 Determining the amount of 4-CBA and p-TOL remain-ing from the manufacture of PTA is often required.This testmethod is suitable for setting specifications and could be usedas an internal quality control tool