分享
ASTM_D_7729_-_12.pdf
下载文档

ID:171548

大小:124.11KB

页数:5页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_7729_ _12
Designation:D772912Standard Practice forDetermining and Expressing Precision of MeasurementResults,in the Analysis of Water,as Relative StandardDeviation,Utilizing DQCALC Software1This standard is issued under the fixed designation D7729;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This Practice describes a procedure for developing agraphical model of relative standard deviation vs concentrationfor a analytical methods used in the analysis of water(methodsthat are subject to non-additive random errors)for the purposeof assigning a statement of noise or randomness to analyticalresults(commonly referred to as a precision statement),ineither a manual or an automated fashion.1.2 Data analysis and modeling is done with D19 AdjunctDQCALC(an Excel based tool).1.3 The values stated in SI units are to be regarded as thestandard.The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Introduction2.1 An understanding of the uncertainty associated withmeasurement results is necessary for evaluating the utility ofthose results.Without a reported uncertainty estimate,users ofmeasurement results are unable to determine if the data aresufficiently precise for any specific data use.2.2 Measurement Uncertainty is most generally understoodto be“a parameter characterizing the dispersion of the quantityvalues being attributed to a measurand”(from InternationalVocabulary of Metrology(VIM)2.26).This definition can beimplemented as an expression(“uncertainty statement”)asso-ciated with an reported measurement that represents thestatistically based(TypeAestimate)dispersion of experimentalresults around a reported value.2.3 There is no universally agreed upon format or nomen-clature for uncertainty statements.The literature offers sugges-tions ranging from simple expressions of standard deviation or“fractional uncertainty”(standard deviation divided by re-ported result)to confidence intervals to detailed“uncertaintyreports”.2.4 In addition to the“random”errors encompassed in theideas expressed in 1.1 and 1.2,above,there are also“system-atic”errors,biases,that can be considered as part of uncer-tainty.The literature is not consistent on how unknown bias isconsidered in an uncertainty statement.For purposes of thisStandard,bias is assumed to have been corrected for orinsignificant in the reported results,and bias is not specificallyincorporated in the proposed uncertainty statement.2.5 For purposes of this Standard,the terms“MU”,uncer-tainty statement,or measurement uncertainty will be usedsynonymously to designate the expression accompanying mea-surement results for the purpose of assessing the utility of thoseresults.2.6 This Standard proposes the use of fractional uncertaintyor Relative Standard Deviation(RSD)as the expression ofMU.2.7 Traditionally,in the generation and publication of datarelated to the analysis of water,a continuous function(model)describing the relationship of uncertainty(as standard devia-tion)to concentration is not available.To compensate for thislack,discrete points bounding certain levels of uncertainty arecalculated,for example,“detection limits”(typically around33%RSD)and“quantitation limits”(often around 10%RSD).Results are flagged to indicate their relationship to one of theselimits.Alternatively,this Practice directs the creation of amodel of uncertainty(RSD vs concentration)which allowsassignment of a discrete uncertainty estimate to any resultvalue measured within the range of modeled data.2.8 This Practice is based on the use of the DQCALCsoftware that was developed to simplify the calculation of theIQE Inter-laboratory Quantitation Estimate(D6512).ThisPractice is restricted to the development of an uncertaintymodel for the reporting of MU within a single laboratory.In1This practice is under the jurisdiction of ASTM Committee D19 on Water andis the direct responsibility of Subcommittee D19.02 on Quality Systems,Specification,and Statistics.Current edition approved April 1,2012.Published September 2012.DOI:10.1520/D772912.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 addition to providing an estimate of single-laboratory measure-ment uncertainty,the DQCALC software automatically calcu-lates LC from Curie,equivalent to EPAs MDL,and theASTM Detection Estimate for a single lab(this utilizes a“3sigma”tolerance interval rather than the standard confidenceinterval).2.9 This Practice provides the tools to allow

此文档下载收益归作者所有

下载文档
猜你喜欢
你可能关注的文档
收起
展开