分享
ASTM_D_7884_-_13.pdf
下载文档

ID:171172

大小:129.21KB

页数:5页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_7884_ _13
Designation:D788413Standard Test Method forDetermination of 4-Carboxybenzaldehyde and p-Toluic Acidin Purified Terephthalic Acid by Reverse Phase HighPerformance Liquid Chromatography1This standard is issued under the fixed designation D7884;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers the determination of the4-Carboxybenzaldehyde(4-CBA)and p-Toluic acid(p-TOL)in purified terephthalic acid(PTA)by reverse phase highperformance liquid chromatography(HPLC).This method isapplicable for 4-CBAfrom 2 to 500 mg/kg and for p-TOLfrom10 to 500 mg/kg,respectively.1.2 In determining the conformance of the test results usingthis method to applicable specification,results shall be roundedoff in accordance with the rounding-off method of PracticeE29.1.3 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD4790 Terminology of Aromatic Hydrocarbons and RelatedChemicalsD6809 Guide for Quality Control and Quality AssuranceProcedures for Aromatic Hydrocarbons and Related Ma-terialsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE682 Practice for Liquid Chromatography Terms and Rela-tionshipsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 ISO Document:3EN ISO 8213 Chemical products for industrial useSampling techniquesSolid chemical products in theform of particles varying from powders to coarse lumps2.3 Other Document:4OSHA Regulations,29 CFR paragraphs 1910.1000 and1910.12003.Summary of Test Method3.1 Reverse Phase HPLC MethodPTAsample is dissolvedin ammonium hydroxide solution,and a fixed volume of thissolution is injected into a high performance liquid chromato-graph equipped with a UV detector.A C18 chemically bondedcolumn is used to separate the impurities 4-CBA and p-TOLfrom PTA.The external standard calibration is used forquantification.4.Significance and Use4.1 The presence of 4-CBA and p-TOL in PTA used for theproduction of polyester is undesirable because they can slowdown the polymerization process and 4-CBA imparts color-ation to the polymer due to thermal instability.4.2 Determining the amount of 4-CBA and p-TOL remain-ing from the manufacture of PTA is often required.This testmethod is suitable for setting specifications and for use as aninternal quality control tool where these products are producedor are used.5.Apparatus5.1 High Performance Liquid Chromatograph(HPLC)any HPLC capable of pumping the mobile phase at flow rates1This test method is under the jurisdiction of ASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct responsibility ofSubcommittee D16.02 on Oxygenated Aromatics.Current edition approved Aug.1,2013.Published October 2013.DOI:10.1520/D7884-13.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute(ANSI),25 W.43rd St.,4th Floor,New York,NY 10036,http:/www.ansi.org.4Available from U.S.Government Printing Office Superintendent of Documents,732 N.Capitol St.,NW,Mail Stop:SDE,Washington,DC 20401,http:/www.access.gpo.gov.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 between 0.1 and 2.0 mL/min,with a pressure between 0 and 40MPa and a pulsation of less than 1%full scale deflection underthe test conditions described in Table 1.The S/N(signal tonoise)ratio should be 3:1 or greater for 2 mg/kg 4-CBAand 10mg/kg p-TOL.5.2 Sample Injection Systemcapable of injecting 1 to 25L,using either partial or full loop mode,with a repeatabilityof 61%.5.3 DetectorVariable Wavelength Ultraviolet PhotometricDetector(VWD),Multi-wavelength Detector,or PhotometricDiode Array Detector(PDA)capable of operating at 240 and254 nm.5.4 Column Ovenany suitable HPLC column oven(blockheating or air circulating)capable of maintaining a constanttemperature of 61C within the range of 20 to 70C.5.5 Chromatography Data System.5.6 HPLC Columns:5.6.1 A stainless steel HPLC column packed with an octa-decylsilane(C18)chemically bonded silica stationary ph

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开