分享
ASTM_D_7201_-_06_2011.pdf
下载文档

ID:170778

大小:518.71KB

页数:24页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_7201_ _06_2011
Designation:D720106(Reapproved 2011)Standard Practice forSampling and Counting Airborne Fibers,Including AsbestosFibers,in the Workplace,by Phase Contrast Microscopy(with an Option of Transmission Electron Microscopy)1This standard is issued under the fixed designation D7201;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice2describes the determination of the con-centration of fibers,expressed as the number of such fibers permillilitre of air,using phase contrast microscopy and optionallytransmission electron microscopy to evaluate particulate mate-rial collected on a membrane filter in the breathing zone of anindividual or by area sampling in a specific location.Thispractice is based on the core procedures provided in theInternational Organization for Standardization(ISO)StandardISO 8672(1)3,the National Institute for Occupational andHealth(NIOSH)Manual of Analytical Methods,NIOSH 7400(2),and the Occupational Safety and Health Administration(OSHA)Method ID 160(3).This practice indicates the impor-tant points where these methods differ,and provides informa-tion regarding the differences,which will allow the user toselect the most appropriate procedure for a particular applica-tion.However,selecting portions of procedures from differentpublished methods generally requires a user to report that theyhave used a modification to a method rather than claim theyhave used the method as written.1.2 The practice is used for routine determination of anindex of occupational exposure to airborne fibers in work-places.Workplaces are considered those places where workersare exposed to airborne fibers including asbestos.Additionalinformation on sampling strategies,sample collection(includ-ing calibration)and use of sample results for asbestos abate-ment projects is provided in a standard Practice for AirMonitoring for Management of Asbestos-Containing Materials(WK 8951)currently being considered by ASTM subcommit-tee E06.24.A further practice has been approved for thespecific purpose of sampling and counting airborne fibers inmines and quarries(Practice D7200),although the practiceherein may also be used for this purpose.The current practicemay be used as a means of monitoring occupational exposureto asbestos fibers when asbestos fibers are known a priori to bepresent in the airborne dust.The practice gives an index ofairborne fiber concentration.This practice may be used inconjunction with electron microscopy(See Appendix X1)forassistance in identification of fibers.This practice may be usedfor other materials such as fibrous glass,or man-made mineralfibers by using alternate counting rules(see Annex A4).1.3 This practice specifies the equipment and procedures forsampling the atmosphere in the breathing zone of an individualand for determining the number of fibers accumulated on afilter membrane during the course of an appropriately-selectedsampling period.The practice may also be used to sample theatmosphere in a specific location or room of a building(areasampling),where this may be helpful in assessing exposure toworkers handling fiber-containing products.1.4 The ideal working range of this test practice extendsfrom 100 fibers/mm2to 1300 fibers/mm2of filter area.For a1000-L air sample,this corresponds to a concentration rangefrom approximately 0.04 to 0.5 fiber/mL(or fiber/cm3).Lowerand higher ranges of fiber concentration can be measured byreducing or increasing the volume of air collected.However,when this practice is applied to sampling the presence of other,non-asbestos dust,the level of total suspended particulate mayimpose an upper limit to the volume of air that can be sampledif the filters produced are to be of appropriate fiber loading forfiber counting.1.5 Users should determine their own limit of detectionusing the procedure in Practice D6620.For Reference theNIOSH 7400 method gives the limit of detection as 7 fibers/mm2of filter area.For a 1000 L air sample,this corresponds toa limit of detection of 0.0027 fiber/mL(or fiber/cm3).ForOSHA method ID 160 the limit of detection is given as 5.5fibers/mm2of filter area.For a 1000 L air sample,thiscorresponds to a limit of detection of 0.0022 fiber/mL(orfiber/cm3).1This practice is under the jurisdiction ofASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.04 on Workplace Air Quality.Current edition approved Oct.1,2011.Published October 2011.Originallyapproved in 2006.Last previous edition approved in 2006 as D7201 06.DOI:10.1520/D7201-06R11.2This test method is based on NIOSH 7400,OSHA Method ID 160,and ISO8672.Users of this ASTM standard are cautioned that if they wish to comply withone of these specific procedures exactly they should follow that procedure,otherwise

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开