温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_6904_
_03_2013
Designation:D690403(Reapproved 2013)Standard Practice forResistance to Wind-Driven Rain for Exterior CoatingsApplied on Masonry1This standard is issued under the fixed designation D6904;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice is for the evaluation of the ability ofcoatings to resist the passage of water through masonry blockwhen exposed to water spray and air pressure.1.2 The values stated in inch-pound units are to be regardedas standard.The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2D1475 Test Method For Density of Liquid Coatings,Inks,and Related ProductsD3924 Specification for Environment for Conditioning andTesting Paint,Varnish,Lacquer,and Related MaterialsD3925 Practice for Sampling Liquid Paints and RelatedPigmented Coatings2.2 Federal Standard:TT-C-555B Coating,Textured(For Interior and ExteriorMasonry Surfaces)33.Summary of Practice3.1 Typically 8 by 16 by 2 in.masonry blocks are coatedwith block filler and then coated with the masonry paint andallowed to cure.The coated blocks are then secured to a testapparatus and exposed for 24 h to continuous water spray andair pressure or as agreed upon between manufacturer andsupplier.Upon completion of the exposure,the blocks areremoved,evaluated for visible water leaks or weight gain,orboth.4.Significance and Use4.1 This practice is meant to simulate the ability of a coatingsystem applied to a masonry block to withstand exposure tocontinuous water spray(rain)and a dynamic pressure equiva-lent to a 98 mph wind velocity without exhibiting water leaksor weight gain,or both.5.Apparatus5.1 The testing box is assembled from transparent plasticpanels12-in.thick and typically of the dimensions as shown inFig.1.Three openings on the side,6 by 12 in.,are provided sothat the coated side of the three blocks may be positioned fortest.The openings on the top of the apparatus for the air inletand manometer connection shall not be less than 3 in.apart tomake certain that air inlet turbulence will not effect themanometer readings.A spray tube shall be constructed from12-in.plastic tubing with three fish-tail nozzles.4Attachment tothe testing box includes a water-filled U-tube manometer,source of compressed air,clamps and angle irons for securelyfastening the test panels to the box,and a drain outlet.Also,illustrated is a simple air pressure regulator consisting of aT-tube with the leg(foot)of the tube placed in a water filledbeaker at a depth of slightly greater than 5 in.This set up is alsoa safety device.Any sudden increase in air pressure will bevented harmlessly.The apparatus outlined above was derivedfrom that shown in Federal Specification TT-C-555B.Appara-tus and substrates of other dimensions can be used as agreedupon between manufacturer and supplier.The duration ofexposure and water pressure used will also be agreed uponbetween manufacturer and user.6.Reagents and Materials6.1 Three 8 by 16 by 2 in.Patio Blocks.6.2 Stiff Bristle Brush.1This practice is under the jurisdiction of ASTM Committee D01 on Paint andRelated Coatings,Materials,and Applications and is the direct responsibility ofSubcommittee D01.47 on Concrete,Stone and Masonry Treatments.Current edition approved June 1,2013.Published June 2013.Originallyapproved in 2003.Last previous edition approved in 2007 as D6904 03(2007).DOI:10.1520/D6904-03R13.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from U.S.Government Printing Office Superintendent of Documents,732 N.Capitol St.,NW,Mail Stop:SDE,Washington,DC 20401,http:/www.access.gpo.gov.4Federal Specification TT-C-555B,Amendment No.1,dated August 5,1975,U.S.Government Printing Office.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 6.3 Mortite or Rubber Gasket,to assure a tight fit of thepatio blocks to the test apparatus.6.4 Clamps and Angle Irons.6.5 Wind-Driven Rain Apparatus,(an example is shown inFig.1).6.6 Source of Compressed Air.6.7 Water Source.7.Sampling7.1 Sampling of both block filler,if used,and topcoat shallbe conducted in accordance with procedures outlined inPractice D3925.8.Procedure8.1 Prepare patio