分享
ASTM_D_7976_-_14.pdf
下载文档

ID:170091

大小:67.85KB

页数:2页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_D_7976_ _14
Designation:D797614Standard Specification forPurified Terephthalic Acid(PTA)1This standard is issued under the fixed designation D7976;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This specification covers purified terephthalic acid(PTA)for use in the manufacturing of polymers.Someexamples include the production of polyesters for fiber,filament,yarn,film,coating,bottle and resin applications.1.2 The following applies to all specified limits in thisspecification:for purposes of determining conformance withthis specification,an observed value or a calculated value shallbe rounded off to the nearest unit in the last right-hand digitused in expressing the specification limit,in accordance withthe rounding-off method of Practice E29.1.3 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.4 Consult current OSHA regulations,suppliers SafetyData Sheets,and local regulations for all materials used in thisspecification.1.5 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2D7881 TestMethodforDeterminationof4-Carboxybenzaldehyde and p-Toluic Acid in PurifiedTerephthalic Acid by Capillary Electrophoresis with Re-verse Voltage ModeD7882 TestMethodforDeterminationof4-Carboxybenzaldehyde and p-Toluic Acid in PurifiedTerephthalic Acid by Capillary Electrophoresis with Nor-mal Voltage ModeD7883 TestMethodforDeterminationof4-Carboxybenzaldehyde and p-Toluic Acid in PurifiedTerephthalic Acid by Weak Anion Exchange High Perfor-mance Liquid ChromatographyD7884 TestMethodforDeterminationof4-Carboxybenzaldehyde and p-Toluic Acid in PurifiedTerephthalic Acid by Reverse Phase High PerformanceLiquid ChromatographyE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE300 Practice for Sampling Industrial Chemicals2.2 Other Documents:OSHA Regulations,CFR 29 paragraphs 1910.1000 and1910.120033.Terminology3.1 Definitions:3.1.1 purified terephthalic acid,n(C8H6O4)molecularweight,166.13;white crystalline solid or powder;sublimes,402 to 404C;abbreviated as PTA(CAS#100-21-0).3.1.2 4-carboxybenzaldehyde,n(C8H6O3)molecularweight,150.13;white to yellow crystalline solid or powder;melting point,247C;abbreviated as 4-CBA(CAS#619-66-9).3.1.3 p-toluic acid,n(C8H8O2)molecular weight,136.15;white crystalline solid or powder;melting point,180 to 181C;abbreviated as p-TOL(CAS#99-94-5).1This specification is under the jurisdiction of ASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct responsibility ofSubcommittee D16.02 on Oxygenated Aromatics.Current edition approved Dec.1,2014.Published January 2015.DOI:10.1520/D7976-14.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from U.S.Government Printing Office Superintendent of Documents,732 N.Capitol St.,NW,Mail Stop:SDE,Washington,DC 20401,http:/www.access.gpo.gov.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 4.Properties4.1 PTA shall conform to the following requirements:PropertySpecificationASTM Test MethodA4-CBA,max,mg/kg25D7881 or D7882 orD7883 or D78844-CBA plus p-TOL,max,mg/kg190D7881 or D7882 orD7883 or D7884AIf more than one method is listed,the producer and user should agree on thereferee method.5.Sampling5.1 The material shall be sampled in accordance withPractice E300.6.Keywords6.1 purifiedterephthalicacid;p-toluicacid;4-carboxybenzaldehydeASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard.Users of this standard are expressly advised that determination of the validity of any such patent rights,and the riskof infringement of such rights,are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised,either reapproved or withdrawn.Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters.Your comments will receive careful consideration at a meeting of theresponsible technical committee,which you may attend.If you feel that your comments have not received a fair hearing you shouldmake

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开