TM_E_2543_ _08_2014
Designation:E254308(Reapproved 2014)Standard Specification forPortable Air Heaters Used at Personnel DecontaminationStations and Shelters1This standard is issued under the fixed designation E2543;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This specification is used to standardize the portable airheaters used on personnel decontamination lines to insure theheaters provide sufficient heated air for personnel comfortbefore,during,and after the decontamination for as long asthey are needed during the emergency.NOTE1These heaters are not intended to be used for the decontami-nation for any other surface or material.Also,these heaters are intendedto be portable and easy to use by first responders during a chemical,biological,radiological,nuclear,and explosive(CBRNE)event.1.2 This specification contains a specification section and atest methods section so users need to refer to the sectionapplicable to their needs when using this standard specifica-tion.1.3 The values stated in SI units are to be regarded asstandard.The values given in parentheses are for informationonly.NOTE2The U.S.first responder personnel using the equipmentmanufactured under this standard are not likely to be familiar with SI unitsso English units need to be included as part of the system documentationand shown on control panels for any equipment sold to U.S.organizations.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2D3195 Practice for Rotameter CalibrationE11 Specification for Woven Wire Test Sieve Cloth and TestSieves2.2 NFPA Standard:3NFPA 70 National Electrical Code2.3 NIST Standard:4Recommended Practice Guide Special Publication 960-12 Stopwatch and Timer Calibrations3.Terminology3.1 Definitions:3.1.1 decontamination,nprocess of reducing or eliminat-ing the hazards associated with chemical,biological,or radio-logical contamination.3.1.1.1 DiscussionThemeansofdecontaminatingpersonnel,equipment,orareasincludeabsorption,neutralization,weathering,and physical removal of the con-taminant and hazards associated with nuclear,biological,orchemical(NBC)agents.4.Classification4.1 There will be no attempt to classify into categories thedifferent types of portable air heaters that can fall under thisspecification since this specification will only address theminimum requirements these heaters shall satisfy.5.Ordering Information5.1 Personnel ordering portable air heaters using this speci-fication as a basis for their order should be aware that thisspecification is the minimum requirement for these types ofdevices and any needs beyond these minimum requirementsshall be stated in the request for quote.6.Mechanical Properties6.1 The heater materials of construction shall be easilycleaned of surface mud and grime with no degradation of theunits ability to perform its function.6.2 The preferred fuels for the heater section of the portableair heater are diesel fuel,gasoline,or bottled propane gas.If1This specification is under the jurisdiction of ASTM Committee E54 onHomeland Security Applications and is the direct responsibility of SubcommitteeE54.03 on Decontamination.Current edition approved June 1,2014.Published June 2014.Originallyapproved in 2008.Last previous edition approved in 2008 as E2543 08.DOI:10.1520/E2543-08R14.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from National Fire Protection Association(NFPA),1 BatterymarchPark,Quincy,MA 02169-7471,http:/www.nfpa.org.4Available from National Institute of Standards and Technology(NIST),100Bureau Dr.,Stop 1070,Gaithersburg,MD 20899-1070,http:/www.nist.gov.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 electricity is used,the circuit shall be no more than 120 V,30A,single phase,and shall conform to NFPA 70 for outdoorusage.7.Performance Requirements7.1 Be able to provide a continuous flow of warm airbetween 27 and 35C(80 and 95F)at a flow rate of not lessthan 0.24 m3/s(500 ft3/min).7.2 The input line shall be filtered using an ASTM Number7 filter(manufactured according to Specification E11)toremove solid contaminants that might damage the equipmentor injure the personnel in the shelter.NOTE3The air inlet will provide suction to the area around the inlet.The user may wish to provide a design to prevent covering or

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开