分享
ASTM_E_2063_-_12.pdf
下载文档

ID:169791

大小:61.49KB

页数:2页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_E_2063_ _12
Designation:E206312Standard Practice forCalibration and Functionality Checks Used in ForensicPsychophysiological Detection of Deception(Polygraph)Examinations1This standard is issued under the fixed designation E2063;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice provides guidelines for calibration andinstrumentation(both analog and computerized systems)ac-tively used in the psychophysiological detection of deception(verification of truth).As a minimum,such instrumentationshall simultaneously record an individuals respiratory,exoso-matic electrodermal,and cardiovascular activity.1.2 Analog polygraphs shall be calibrated by the psycho-physiological detection of deception(PDD)examiner,manufacturer,or factory-authorized individual.1.3 Computerized instrumentation shall be calibrated by themanufacturer or factory-authorized individual.1.4 The PDD examiner or factory-authorized individualshall perform functionality checks to ensure instrumentation isoperating properly.1.5 This practice does not prohibit additional componentswhich may be offered as supplemental measurements ofphysiological change.Additional recording components(suchas movement sensors)may be used in addition to,but notreplace,the required minimum components and these addi-tional components shall meet the manufacturers specificationsfor calibration.2.Referenced Documents2.1 ASTM Standards:2E1954 Practice for Conduct of Research in Psychophysi-ological Detection of Deception(Polygraph)E2000 Guide for Minimum Basic Education and Training ofIndividuals Involved in the Detection of Deception(PDD)E2035 Terminology Relating to Forensic Psychophysiology2.2 Other Document:Manufacturer Manual(s)for System(s)in Use3.Terminology3.1 Definitions of TermsSee Terminology E2035.3.2 Terminology may vary according to different manufac-turers.4.Significance and Use4.1 This practice sets forth the minimum requirements forcalibration and functionality checks when conducting PDDexaminations and related activities.For additional informationsee Practice E1954 and Guide E2000.5.Minimum Requirements for Calibration andFunctionality Checks of Polygraph Instrumentation5.1 A recorded chart shall be created demonstrating correctfunctioning of the instrument.This chart will be maintained fora minimum period of one year.5.1.1 This chart shall contain the following information,asapplicable:name of person performing calibration or function-ality check,time and date,location,manufacturer,model,andinstrument identification.5.1.2 All notations,settings,and adjustments shall beclearly and permanently noted on the chart(either marked byhand or,in the case of computerized instrumentation,electroni-cally recorded).5.1.3 All calibration and functionality checks shall be con-ducted in accordance with the manufacturers specifications.6.Calibration Check(Analog Instruments)6.1 Calibration or functionality checks shall be conducted inaccordance with the manufacturers specifications.6.2 At any time a malfunction is identified,the instrumentshall not be used to conduct a PDD examination until thatmalfunction has been corrected as demonstrated by an addi-tional calibration or functionality check.6.3 A record in the form of a calibration or functionalitychart shall be kept identifying the time and date,instrumentidentification,and who conducted the calibration or function-ality check.1This practice is under the jurisdiction of ASTM Committee E52 on ForensicPsychophysiology and is the direct responsibility of Subcommittee E52.02 onInstrumentation.Current edition approved May 1,2012.Published June 2012.Originallyapproved in 2000.Last previous edition approved in 2011 as E2063 05(2011).DOI:10.1520/E2063-12.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 6.3.1 This record shall be maintained for a minimum of oneyear.7.Calibration or Functionality Check for ComputerInstruments7.1 Functionality or calibration checks shall be conducted inaccordance with the manufacturers specifications.7.2 At any time a malfunction is identified,the instrumentshall not be used to conduct a PDD examination until thatmalfunction has been corrected as demonstrated by a calibra-tion or functionality check.7.3 A record in the form of a calibration or functionalitychart in printed or digital format shall be kept identifying thedate,instrument identification,and by whom the calibration orfunctionality check was conducted.7.3.1 This record shall be maintained for a minimu

此文档下载收益归作者所有

下载文档
猜你喜欢
你可能关注的文档
收起
展开