TM_E_2377_
_10
Designation:E237710Standard Specification forShelter,Electrical Equipment,Lightweight1This standard is issued under the fixed designation E2377;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This specification covers two types of lightweight elec-trical equipment shelters designed for transport on theM1152A1,M1152A1 with B2 Armor Kit,M1037,and M1097High Mobility Multipurpose Wheeled Vehicle(HMMWV).These shelters are transported by rail,air,marine and highwaywhen mounted or dismounted from their vehicles.1.2 ClassificationThe shelters will be of the followingtypes,as specified(see 6.2).1.2.1 Type IShelter,Electrical Equipment,Lightweight(w/o Tunnel,17-2-0035-1).1.2.2 Type IIIShelter,Electrical Equipment,Lightweight,Modified,General Purpose(w/Tunnel,17-2-0035-3).1.3 The values stated in inch-pound units are to be regardedas standard.The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4 The following safety hazards caveat pertains only to thetest required portion,Section 4,of this specification:Thisstandard does not purport to address all of the safety concerns,if any,associated with its use.It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory require-ments prior to use.2.Referenced Documents2.1 ASTM Standards:2E1851 Test Method for Electromagnetic Shielding Effec-tiveness of Durable Rigid Wall Relocatable StructuresE1925 Specification for Engineering and Design Criteria forRigid Wall Relocatable Structures2.2 Commercial Standard:3SAE-AS8090 Equipment,TowedAerospace Ground,Mobil-ity2.3 Federal Standard:4FED-STD-595 Colors Used in Government Procurement2.4 Military Standards:4MIL-STD-209 Slinging and Tiedown Provisions for Liftingand Tying Down Military EquipmentMIL-STD-810 Environmental Test Methods and Engineer-ing GuidelinesMIL-STD-1366 Transportability CriteriaMIL-C-53072 Chemical Agent Resistant Coating(CARC)System Application Procedures and Quality Control In-spection2.5 Military Handbook:4MIL-HDBK-1791 Designing for Internal Aerial Delivery inFixed Winged Aircraft2.6 ACGIH Documents:5Threshold Limit Values2.7 Drawings:617-1-8565 Extension Kit,Pintle17-1-8584 Mounting Kit Shelter To HMMWV17-2-0035 Interface Control Drawing for,Shelter,ElectricalEquipment,Lightweight,Types I and III13228E1639 Standard Camouflage,Pattern For Shelter,Lightweight,Multipurpose3.General Requirements3.1 First ArticleWhen specified(see 6.3),a sample shallbe subjected to first article inspection in accordance with 4.1.1.A first article is defined as a preproduction or an initialproduction sample consisting of one or more of each type ofcompleted shelters.1This specification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.53on Materials and Processes for Durable Rigidwall Relocatable Structures.Current edition approved Oct.1,2010.Published October 2010.Originallyapproved in 2003 as PS 138-03.Last previous edition approved in 2004 asE2377 04.DOI:10.1520/E2377-10.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from SAE International(SAE),400 Commonwealth Dr.,Warrendale,PA 15096-0001,http:/www.sae.org.4Available from Standardization Documents Order Desk,DODSSP,Bldg.4,SectionD,700RobbinsAve.,Philadelphia,PA19111-5098,http:/dodssp.daps.dla.mil.5Available from American Conference of Governmental Industrial Hygienists,Inc.(ACGIH),1330 Kemper Meadow Dr.,Cincinnati,OH 45240,http:/www.acgih.org.6Available from Shelter Technology,Engineering&Fabrication Directorate,U.S.Army Natick Soldier RD&E Center,ATTN:RDNS-ST,Kansas Street,Natick,MA 01760-5018,http:/www.natick.army.mil.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 3.2 Physical Performance Requirements:3.2.1 Weight and PayloadThe shelter weight and payloadcapacity of each shelter type shall be as listed in Table 1.Themaximum shelter weight listed does not include the weight ofthe Mounting Kit and Pintle Extension and their attachinghardware.The shelter shall be capable of accepting the payloaddistribution specified in the contract or purchase order(see6.2).The Contractor shall fashion an appropriate simulatedpayload design to be used for all testing.This payload designshall be approved by the procuring agency prior to its use inany test.3.2.2 Parts InterchangeabiIity:3.2.2.1 Spare PartsThe spare parts are listed in T