温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_E_1341_
_16
Designation:E134116Standard Practice forObtaining Spectroradiometric Data from Radiant Sourcesfor Colorimetry1This standard is issued under the fixed designation E1341;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.INTRODUCTIONThe fundamental procedure for characterizing the color and absolute luminance of radiant sourcesis to obtain the spectroradiometric data under specified measurement conditions,and from these datato compute CIE chromaticity coordinates and luminance values based on the CIE 1931 StandardObserver.The considerations involved and the procedures to be used to obtain precision spectrora-diometric data for this purpose are contained in this practice.The values and procedures for computingCIE chromaticity coordinates are contained in Practice E308.This practice includes minor modifi-cations to the procedures given in Practice E308 that are necessary for computing the absoluteluminance of radiant sources.1.Scope1.1 This practice prescribes the instrumental measurementrequirements,calibration procedures,and physical standardsneeded for precise spectroradiometric data for characterizingthe color and luminance of radiant sources.1.2 This practice lists the parameters that must be specifiedwhen spectroradiometric measurements are required in specificmethods,practices,or specifications.1.3 This practice describes the unique calculation proce-dures required to determine basic colorimetric data of luminoussources.1.4 This practice is general in scope rather than specific asto instrument,object,or material.1.5 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2E275 Practice for Describing and Measuring Performance ofUltraviolet and Visible SpectrophotometersE284 Terminology of AppearanceE308 Practice for Computing the Colors of Objects by Usingthe CIE SystemE387 Test Method for Estimating Stray Radiant Power Ratioof Dispersive Spectrophotometers by the Opaque FilterMethodE925 Practice for Monitoring the Calibration of Ultraviolet-Visible Spectrophotometers whose Spectral Bandwidthdoes not Exceed 2 nmE958 Practice for Estimation of the Spectral Bandwidth ofUltraviolet-Visible Spectrophotometers2.2 NIST Publications:NIST Technical Note 594-1 Fundamental Principles of Ab-solute Radiometry and the Philosophy of the NBS Pro-gram(19681971)3NIST Technical Note 594-3 Photometric Calibration Proce-dures32.3 CIE Publications:CIE Publication 015:2004 Colorimetry,3rd ed.41This practice is under the jurisdiction of ASTM Committee E12 on Color andAppearance and is the direct responsibility of Subcommittee E12.06 on Display,Imaging and Imaging Colorimetry.Current edition approved Nov.1,2016.Published November 2016.Originallyapproved in 1991.Last previous edition approved in 2011 as E1341 06(2011)1.DOI:10.1520/E1341-16.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from National Institute of Standards and Technology(NIST),100Bureau Dr.,Stop 1070,Gaithersburg,MD 20899-1070,http:/www.nist.gov.4Available from U.S.National Committee of the CIE(International Commissionon Illumination),C/o Alan Laird Lewis,282 E.Riding,Carlisle,MA 01741,http:/www.cie-usnc.org.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 CIE Publication No.38 Radiometric and Photometric Char-acteristics of Materials and their Measurement,19774CIE Publication No.63 Spectroradiometric Measurement ofLight Sources,198442.4 IES Standard:IES Guide to Spectroradiometric Measurements,198352.5 ANSI Standard:ANSI/IES RP-16-1980 Nomenclature and Definitions forIlluminating Engineering53.Terminology3.1 Definitions:3.1.1 The definitions of appearance terms in TerminologyE284 are applicable to this practice.4.Summary of Practice4.1 Procedures are given for selecting the types and oper-ating parameters of spectroradiometers used to produce datafor the calculation of CIE tristimulus values and other colorcoordinates to describe the colors of radiant sources.Theimportant steps of the calibration of such instruments,and thestandards required for these steps,are described.Parametersare identified that must be specified when spectroradiometricmeasurements are required in specific methods or oth