分享
ASTM_E_1375_-_90_2002.pdf
下载文档

ID:168945

大小:65.36KB

页数:6页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_E_1375_ _90_2002
Designation:E 1375 90(Reapproved 2002)Standard Test Method forMeasuring the Interzone Attenuation of Furniture PanelsUsed as Acoustical Barriers1This standard is issued under the fixed designation E 1375;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon(e)indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test method is one of a series for the measurement and evaluation of acoustical componentsaffecting speech privacy in open-plan spaces.This test method provides a means of objectivelymeasuring the relevant acoustical characteristics of one component of the open-plan space,furniturepanels used as acoustical barriers.1.Scope1.1 This test method covers the measurement of the inter-zone attenuation of furniture panels used as acoustical barriersin open-plan spaces to provide speech privacy or soundisolation between working positions.21.2 This test procedure was originally developed using thefoot-pound system of units for prescribing measurement posi-tions and distances.However,the use of SI units is preferred byASTM.For this reason,dimensions are provided in SI units,with approximate foot-pound conversions indicated.1.2.1 Unless otherwise qualified,all dimensions specified inthis test method shall be understood to have a tolerance of 625mm(61 in.),even though the indicated approximate conver-sions of the numerical dimensions given will not always beaccurate to this extent.All measurements shall be made in SIunits or the corresponding exact foot-pound units.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:C 423 Test Method for Sound Absorption and Sound Ab-sorption Coefficients by the Reverberation Room Method3C 634 Terminology Relating to Environmental Acoustics3E 795 Practices for Mounting Test Specimens DuringSound Absorption Tests3E 1110 Classification for Determination of ArticulationClass3E 1130 Test Method for Objective Measurement of SpeechPrivacy in Open Offices Using Articulation Index3E 1179 Specification for Sound Sources Used for TestingOpen Office Components and Systems32.2ANSI Standards:S1.4 Specification for Sound Level Meters4S1.6 Preferred Frequencies and Band Numbers for Acous-tical Measurements4S1.11 Specification for Octave Band and Fractional-OctaveBand Analog and Digital Filters4S1.12 Specification for Laboratory Standard Microphones43.Terminology3.1 DefinitionsFor definition of terms used in this testmethod see Terminology C 634.The term source point isdefined in Specification E 1179.3.2 Definitions of Terms Specific to This Standard:3.2.1 furniture panela furnishing that does not extend tothe ceiling,and that is used to subdivide an open-plan spaceand provide some degree of visual and acoustical privacy.Furniture panels include interlocking systems furniture andfreestanding screens.1This test method is under the jurisdiction of ASTM Committee E33 onEnvironmentalAcoustics and is the direct responsibility of Subcommittee E33.02 onOpen Plan Spaces.Current edition approved July 27,1990.Published September 1990.2This test method is similar to a procedure developed by the United StatesGovernment General Services Administration,Public Buildings Service,designated“PBS-C.2,Test Method for the Sufficient Verification of Speech Privacy PotentialBased on Objective Measurements including Methods for the Rating of FunctionalInterzone Attenuation and NC-Background,August 1972.”3Annual Book of ASTM Standards,Vol 04.06.4Available from American National Standards Institute,25 W.43rd St.,4thFloor,New York,NY 10036.1Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959,United States.3.2.2 interzone attenuationat a specified position,for aone-third octave-band,the difference between the sound pres-sure level at a nominal reference position 0.9 m(3 ft)from thesound source and the sound pressure level at the point inquestion.3.2.3 nominal interzone attenuationfor a one-thirdoctave-band,at a specified point,the arithmetic mean interzoneattenuation calculated using the interzone attenuation for thepoint in question and for two adjacent positions 0.3 m(1 ft)toeither side.(See Figs.1 and 2.)For example,in Fig.1,thenominal interzone attenuation at the 3.0-m(10-ft)position isthe arithmetic mean of the interzone attenuations at the 2.7,3.0,and 3.3-m(9,10,and 11-ft)positions.4.Summary of Test Method4.1 The test facility is a room constructed such that soundreflections from the walls and ceiling are negligible.The testspecimen is a furniture panel arranged as an acoustical barrier,that is,arranged such th

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开