分享
ASTM_E_1273_-_88_2013.pdf
下载文档

ID:168872

大小:63.01KB

页数:2页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_E_1273_ _88_2013
Designation:E127388(Reapproved 2013)Standard Specification forColor Coding of Reusable Laboratory Pipets1This standard is issued under the fixed designation E1273;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This specification covers a system of color coding forone-mark pipets for identification of nominal capacities,andfor graduated pipets for identification of nominal capacities andunits of sub-division.1.2 This specification applies to one-mark and graduatedpipets of the nominal capacities listed in Table 1 and Table 2,respectively.NOTE1Many pipets not covered by other ASTM standards areincluded in Table 1 and Table 2,in order,firstly,to ensure uniformity ofcolor coding as far as possible for non-standard as well as standard pipetsand,secondly,to reserve suitable codes for possible future standards forother types of pipet.1.3 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2E1157 Specification for Sampling and Testing of ReusableLaboratory Glassware3.Significance and Use3.1 The purpose of this specification is to ensure that if acolor code is used on pipets,all manufacturers will use thesame code;it is not intended as an encouragement of colorcoding if this is not required.4.Color Properties4.1 CodingThe color coding used on one-mark pipetsshall be in accordance with Table 1,and graduated pipets shallbe in accordance with Table 2.4.2 VariationsVariations in the enamels used in the meth-ods of application appropriate for pipets made from differenttypes of glass inevitably result in minor variations of color,andit is therefore not appropriate to specify closely the sevencolors listed in the tables.5.Marking Requirements5.1 The color code shall take the form of color bandsextending at least 150 around the circumference of the pipetand situated not more than 70 mm from the top of the pipet andnot less than 20 mm above the nearest graduation line.5.2 For a code consisting of a single band of color,the bandshall be 5 to 10 mm wide.For a code consisting of two bandsof color,each band shall be 3 to 5 mm wide and the two bandsshall be separated by a space of 2 to 3 mm.Color bands do nothave to be continuous but may be broken as long as they cover40%of the circumference of the pipet.NOTE2Pipets calibrated to deliver by blowing out the last drop shallbe identified by a wide band or two narrow bands permanently marked ontheir top end.6.Sampling and Testing6.1 Sampling and testing shall be in accordance with Speci-fication E1157.7.Keywords7.1 colorcoding;laboratory;pipets1This specification is under the jurisdiction of ASTM Committee E41 onLaboratory Apparatusand is the direct responsibility of Subcommittee E41.01 onApparatusCurrent edition approved Nov.1,2013.Published December 2013.Originallyapproved in 1988.Last previous edition approved in 2008 as E127388(2008).DOI:10.1520/E1273-88R13.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard.Users of this standard are expressly advised that determination of the validity of any such patent rights,and the riskof infringement of such rights,are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised,either reapproved or withdrawn.Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters.Your comments will receive careful consideration at a meeting of theresponsible technical committee,which you may attend.If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards,at the address shown below.This standard is copyrighted by ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959,United States.Individual reprints(single or multiple copies)of this standard may be obtained by contacting ASTM at the ab

此文档下载收益归作者所有

下载文档
你可能关注的文档
收起
展开