分享
ASTM_E_1093_-_91_2012.pdf
下载文档

ID:168451

大小:91.63KB

页数:3页

格式:PDF

时间:2023-03-04

收藏 分享赚钱
温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
TM_E_1093_ _91_2012
Designation:E109391(Reapproved 2012)Standard Specification forGlass Prothrombin Pipet,Disposable1This standard is issued under the fixed designation E1093;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This specification covers a glass disposable Prothrombinpipet suitable for use in micro techniques for estimation ofProthrombin time.1.2 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.3 This precautionary statement pertains only to the testmethod portion,Section 8,of this specification.This standarddoes not purport to address all of the safety concerns,if any,associated with its use.It is the responsibility of the user of thisstandard to establish appropriate safety and health practicesand determine the applicability of regulatory limitations priorto use.2.Referenced Documents2.1 ASTM Standards:2E438 Specification for Glasses in Laboratory Apparatus2.2 ISO Standard:31769 Laboratory GlasswarePipettesColor Coding3.Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 accuracythe expected distribution of mean volumesaround the stated volume.3.1.2 coeffcient of variationthe expected distribution ofindividual volumes around the mean volume.3.1.3 disposableProthrombin pipets which are intended tobe used once only and then discarded.NOTE1Such pipets will only be expected to provide their specifiedperformance during the original operation.4.Classification4.1 This specification covers only one glass pipet as illus-trated in Fig.X1.1.5.Materials and Manufacture5.1 The pipet shall be made of borosilicate glass,Type 1;Class B,or soda lime glass,Type 2,in accordance withSpecification E438.6.Physical Properties6.1 DesignThe Prothrombin pipet shall be made of onepiece construction glass tubing that is straight and with uniformbore and lightly firepolished on both ends.The pipet shall bemade to the dimensions as specified in Fig.X1.1.6.2 DimensionsThe pipet shall be made of tubing with aminimum outside diameter(o.d.)of 2.3 mm with an insidediameter(i.d.)of 1.7 mm.The uniformity of the bore shall be60.05 mm throughout the straight portion of the pipet.Thepipet shall be a minimum of 160 mm long.6.3 CapacityThe pipet shall be calibrated“to deliver”(T.D.)0.1 and 0.2 mL at 20C.Marking shall be as specified in6.5.6.3.1 Accuracy(see 3.1.1)The accuracy from stated vol-ume shall be 62.0%for the 0.1 and 0.2-mL capacity and shallbe determined as specified in 8.1.6.3.2 Coeffcient of Variation(see 3.1.2)The coefficient ofvariation from stated volume for the 0.1 and 0.2-mL capacityshall not exceed 2.0%and shall be determined as specified in8.1.6.4 Graduation LinesThe pipet shall be calibrated andmarked with graduation lines at 0.1 and 0.2 mL from the tip ofthe pipet.The graduation lines shall be 0.3 6 0.1 mm and shallcompletely encircle the tube.6.5 Pipet NomenclatureThe pipet shall be marked with0.1 and 0.2-mL markings slightly above the graduation lines.The pipet may be marked with the inscription T.D.20C,or themanufacturers or vendors name or trademark,or both.6.6 Blow-out DeliveryThe Prothrombin pipet is designedas a dual delivery system for the determinations of coagulationassays.When utilizing the 0.2 mLcalibration line,the tip of thepipet should contact the wall of the receiving vessel and allowthe pipet to drain freely.The remaining quantity of liquid is to1This specification is under the jurisdiction of ASTM Committee E41 onLaboratory Apparatus and is the direct responsibility of Subcommittee E41.01 onApparatus.Current edition approved Nov.1,2012.Published November 2012.Originallyapproved in 1986.Last previous edition approved in 2005 as E1093 91(2005).DOI:10.1520/E1093-91R12.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from ISO,1 Rue de Varembe,Case Postal 56,Crt 1221,Geneva 20,Switzerland.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 be blown out into the center of the receiving vessel.Whenutilizing the 0.1 mL calibration line the contents are to bevigorously blown out into the center of the receiving vesselwith one quick effort.Either one band or two narrow bandsshall encircle the top end of the pipet to signify the contentsmust be blown out as shown in Fig.X1.1.6.7 Color CodingThe pipet shall be color coded forcapacity as specified in ISO Standard 1769 with an“orange”color band that is 6 6 2 mm wide and located 16 6 2 mm fromthe top of the pipet as shown in Fig.X1.1.6.8 Marking PermanencyGraduation lines,inscriptions,and numeric

此文档下载收益归作者所有

下载文档
猜你喜欢
你可能关注的文档
收起
展开