温馨提示:
1. 部分包含数学公式或PPT动画的文件,查看预览时可能会显示错乱或异常,文件下载后无此问题,请放心下载。
2. 本文档由用户上传,版权归属用户,汇文网负责整理代发布。如果您对本文档版权有争议请及时联系客服。
3. 下载前请仔细阅读文档内容,确认文档内容符合您的需求后进行下载,若出现内容与标题不符可向本站投诉处理。
4. 下载文档时可能由于网络波动等原因无法下载或下载错误,付费完成后未能成功下载的用户请联系客服处理。
网站客服:3074922707
ASME_B16
29
2017
AN AM E R IC A N NAT IO NAL STANDARDASME B16.29-2017(Revision of ASME B16.29-2012)Wrought Copper and Wrought Copper Alloy Solder-Joint Drainage Fittings DWVASME B16.29-2017(Revision of ASME B16.29-2012)Wrought Copper andWrought Copper AlloySolder-Joint DrainageFittings DWVAN AMERICAN NATIONAL STANDARDDate of Issuance:December 29,2017The next edition of this Standard is scheduled for publication in 2022.ASME issues written replies to inquiries concerning interpretations of technical aspects of this Standard.Interpretations arepublished on the ASME Web site under the Committee Pages at http:/cstools.asme.org/as they are issued.Errata to codes and standards may be posted on the ASME Web site under the Committee Pages to provide corrections toincorrectlypublisheditems,ortocorrecttypographicalorgrammaticalerrorsincodesandstandards.Sucherratashallbeusedon the date posted.TheCommitteePagescanbefoundathttp:/cstools.asme.org/.Thereisanoptionavailabletoautomaticallyreceiveane-mailnotification when errata are posted to a particular code or standard.This option can be found on the appropriate CommitteePage after selecting“Errata”in the“Publication Information”section.ASME is the registered trademark of The American Society of Mechanical Engineers.ThiscodeorstandardwasdevelopedunderproceduresaccreditedasmeetingthecriteriaforAmericanNationalStandards.TheStandardsCommitteethatapprovedthecodeorstandardwasbalancedtoassurethatindividualsfromcompetentandconcernedinterestshavehadanopportunityto participate.The proposed codeorstandardwasmadeavailable forpublic reviewandcommentthatprovidesanopportunityfor additional public input from industry,academia,regulatory agencies,and the public-at-large.ASME does not“approve,”“rate,”or“endorse”any item,construction,proprietary device,or activity.ASME does not take any position with respect to the validity of any patent rights asserted in connection with any items mentioned in thisdocument,anddoesnotundertaketoinsureanyoneutilizingastandardagainstliabilityforinfringementofanyapplicableletterspatent,norassumeanysuchliability.Usersofacodeorstandardareexpresslyadvisedthatdeterminationofthevalidityofanysuchpatentrights,andtherisk of infringement of such rights,is entirely their own responsibility.Participation by federal agency representative(s)or person(s)affiliated with industry is not to be interpreted as government or industryendorsement of this code or standard.ASME accepts responsibility for only those interpretations of this document issued in accordance with the established ASME proceduresand policies,which precludes the issuance of interpretations by individuals.No part of this document may be reproduced in any form,in an electronic retrieval system or otherwise,without the prior written permission of the publisher.The American Society of Mechanical EngineersTwo Park Avenue,New York,NY 10016-5990Copyright 2017 byTHE AMERICAN SOCIETY OF MECHANICAL ENGINEERSAll rights reservedPrinted in U.S.A.CONTENTSForeword.vCommittee Roster.viCorrespondence With the B16 Committee.viiSummary of Changes.ixList of Changes in Record Number Order.x1Scope.12General.13Description.14Pitch(Slope).15Abbreviations.16Component Size.17Marking.28Material.29Laying Lengths.210Ovality.211Threaded Ends.212Design of Threaded Ends.213Alignment.214Gaging.3Mandatory AppendicesIU.S.Customary Dimensions.14IIReferences.25Nonmandatory AppendixAQuality System Program.26Figure1Size of Fittings.2Tables1Dimensions of Solder-Joint Ends.42Dimensions of Threaded Ends DWV.53Dimensions of DWV Couplings,Extended Bushings,and Adapters.64Dimensions of DWV Soil Pipe Adapters.75Dimensions of DWV C No-Hub Soil Pipe Adapters.86Dimensions of DWV Elbows.97Dimensions of DWV 45 deg Ys.10iii8Dimensions of DWV Tees.119Dimensions of DWV Caps.1110Dimensions of DWV Vent Increasers.1111Dimensions of DWV Closet Flanges.1212Dimensions of DWV Trap Adapters.1313Dimensions of DWV Slip-Joint Ends.13I-1Dimensions of Solder-Joint Ends.15I-2Dimensions of Threaded Ends DWV.16I-3Dimensions of DWV Couplings,Extended Bushings,and Adapters.17I-4Dimensions of DWV Soil Pipe Adapters.18I-5Dimensions of DWV C No-Hub Soil Pipe Adapters.19I-6Dimensions of DWV Elbows.20I-7Dimensions of DWV 45 deg Ys.21I-8Dimensions of DWV Tees.22I-9Dimensions of DWV Caps.22I-10Dimensions of DWV Vent Increasers.22I-11Dimensions of DWV Closet Flanges.23I-12Dimensions of DWV Trap Adapters.24I-13Dimensions of DWV Slip-Joint Ends.24ivFOREWORDStandardization of cast and wrought solder-joint fittings was initiated in Subcommittee 11 of American StandardsAssociation(ASA)SectionalCommittee A40onPlumbingRequirementsand Equipment.Developmentworkculminatedin publication of ASA A40.3-1941.In1949,workonthesefittingswastransferredtoSectionalCommitteeB16ofASA,whichestablishedSubcommittee9(nowSubcommitteeJ).ThefirststandarddevelopedwasapprovedasASAB16.18-1950,CastBronzeSolder-JointFittings.A later joint effort of the Copper and Brass Research Association and the Manufacturers Standardization Society of t