血细胞
分离
常见故障
维护
保养
常见问题处理方法及技巧 张建强 (13801709456)Copyright 2007 Haemonetics Corporation.Haemonetics,Infonal,cardioPAT,Cell Saver,OrthoPAT,SmartSuction,SmartSuction Harmony,and SmartSuction Solo are trademarks or registered trademarks of Haemonetics Corporation in the USA,other countries,or both.显示屏显示屏 控制面板控制面板 离心机离心机 溶液袋支架溶液袋支架 抗凝剂空气监测器抗凝剂空气监测器(ACAD)抗凝剂抗凝剂(AC)泵泵 输送泵输送泵 血液泵血液泵 阀门阀门 电源开关电源开关 献血员管路空气监测器献血员管路空气监测器(DLAD1)献血员管路空气监测器献血员管路空气监测器(DLAD2)献血员压力监测献血员压力监测器器(DPM)血液容器支架环血液容器支架环 内循环容器支架环内循环容器支架环 固定挂销固定挂销 阀门阀门 袖袋袖袋(背后背后)系统压力监测器系统压力监测器(SPM)程序卡插入门程序卡插入门 献血员流量指示灯献血员流量指示灯 (側面側面)称重器称重器 管线光线监测器管线光线监测器(line sensor)血液管道空气监测器血液管道空气监测器(BLAD)献血员流量指示灯献血员流量指示灯 Copyright 2007 Haemonetics Corporation.Haemonetics,Infonal,cardioPAT,Cell Saver,OrthoPAT,SmartSuction,SmartSuction Harmony,and SmartSuction Solo are trademarks or registered trademarks of Haemonetics Corporation in the USA,other countries,or both.一:显示屏.操作面板 Copyright 2007 Haemonetics Corporation.Haemonetics,Infonal,cardioPAT,Cell Saver,OrthoPAT,SmartSuction,SmartSuction Harmony,and SmartSuction Solo are trademarks or registered trademarks of Haemonetics Corporation in the USA,other countries,or both.二:离心机 Copyright 2007 Haemonetics Corporation.Haemonetics,Infonal,cardioPAT,Cell Saver,OrthoPAT,SmartSuction,SmartSuction Harmony,and SmartSuction Solo are trademarks or registered trademarks of Haemonetics Corporation in the USA,other countries,or both.三:阀门 Copyright 2007 Haemonetics Corporation.Haemonetics,Infonal,cardioPAT,Cell Saver,OrthoPAT,SmartSuction,SmartSuction Harmony,and SmartSuction Solo are trademarks or registered trademarks of Haemonetics Corporation in the USA,other countries,or both.四:泵 血液泵血液泵 复合泵识别窗复合泵识别窗 传输泵传输泵 抗凝剂抗凝剂(AC)泵泵 Copyright 2007 Haemonetics Corporation.Haemonetics,Infonal,cardioPAT,Cell Saver,OrthoPAT,SmartSuction,SmartSuction Harmony,and SmartSuction Solo are trademarks or registered trademarks of Haemonetics Corporation in the USA,other countries,or both.五:称重臂 Copyright 2007 Haemonetics Corporation.Haemonetics,Infonal,cardioPAT,Cell Saver,OrthoPAT,SmartSuction,SmartSuction Harmony,and SmartSuction Solo are trademarks or registered trademarks of Haemonetics Corporation in the USA,other countries,or both.六:压力监测器 献血员压力监测器献血员压力监测器(DPM)系统压力监测器系统压力监测器(SPM)Copyright 2007 Haemonetics Corporation.Haemonetics,Infonal,cardioPAT,Cell Saver,OrthoPAT,SmartSuction,SmartSuction Harmony,and SmartSuction Solo are trademarks or registered trademarks of Haemonetics Corporation in the USA,other countries,or both.七:管道空气监测器 血液管路空气监测器血液管路空气监测器(BLAD)献血员管路空气监测器献血员管路空气监测器(DLAD)抗凝剂管路空气监测器抗凝剂管路空气监测器(ALAD)AC 滴注监测器滴注监测器 Copyright 2007 Haemonetics Corporation.Haemonetics,Infonal,cardioPAT,Cell Saver,OrthoPAT,SmartSuction,SmartSuction Harmony,and SmartSuction Solo are trademarks or registered trademarks of Haemonetics Corporation in the USA,other countries,or both.八:光学监测器 杯光电杯光电(O.S)管路监测器管路监测器(L.S)Copyright 2007 Haemonetics Corporation.Haemonetics,Infonal,cardioPAT,Cell Saver,OrthoPAT,SmartSuction,SmartSuction Harmony,and SmartSuction Solo are trademarks or registered trademarks of Haemonetics Corporation in the USA,other countries,or both.九:耗材 Copyright 2007 Haemonetics Corporation.Haemonetics,Infonal,cardioPAT,Cell Saver,OrthoPAT,SmartSuction,SmartSuction Harmony,and SmartSuction Solo are trademarks or registered trademarks of Haemonetics Corporation in the USA,other countries,or both.开机死机 屏幕只显示“MCS+”就停止 原因原因:经常发生在需要更换不同程序卡经常发生在需要更换不同程序卡.由于前一次程序结由于前一次程序结束后未自检就关机束后未自检就关机.处理处理:换回前一次采集程序卡换回前一次采集程序卡,重新启动机器重新启动机器,等机器自检通等机器自检通过结束过结束.Copyright 2007 Haemonetics Corporation.Haemonetics,Infonal,cardioPAT,Cell Saver,OrthoPAT,SmartSuction,SmartSuction Harmony,and SmartSuction Solo are trademarks or registered trademarks of Haemonetics Corporation in the USA,other countries,or both.开机自检失败 原因原因:开机之前已预先安装了耗材开机之前已预先安装了耗材.处理处理:拔掉拔掉DPM,SPM.取下各监测器和阀门内的管道及称重取下各监测器和阀门内的管道及称重器上的血浆袋器上的血浆袋.Copyright 2007 Haemonetics Corporation.Haemonetics,Infonal,cardioPAT,Cell Saver,OrthoPAT,SmartSuction,SmartSuction Harmony,and SmartSuction Solo are trademarks or registered trademarks of Haemonetics Corporation in the USA,other countries,or both.开机出现“The power has been off for a short time”提示.不自检.(code 375)原因原因:由于停电或非正常终止采集程序由于停电或非正常终止采集程序(例例:漏液漏液,献血员不适献血员不适)关闭电源关闭电源.操作人员在重新安装一套新耗材后操作人员在重新安装一套新耗材后,没有仔细认真的阅读屏幕上显示没有仔细认真的阅读屏幕上显示的内容的内容,习惯地按“习惯地按“YES”,选择了“恢复原操作程序”选择了“恢复原操作程序”,使程序无法进使程序无法进行行 处理处理:重新开机重新开机,开机自检后屏幕将提示你选择开机自检后屏幕将提示你选择:1.按“按“NO”键键,已更换了新的耗材已更换了新的耗材.2.按“按“YES”键键,原耗材未被取下原耗材未被取下,需要继续原有采集程序需要继续原有采集程序.Copyright 2007 Haemonetics Corporation.Haemonetics,Infonal,cardioPAT,Cell Saver,OrthoPAT,SmartSuction,SmartSuction Harmony,and SmartSuction Solo are trademarks or registered trademarks of Haemonetics Corporation in the USA,other countries,or both.离心舱清理 原因原因:1.漏液监测器经常报警漏液监测器经常报警.2.离心杯安装不到位离心杯安装不到位.漏液监测器漏液监测器 机械卡爪机械卡爪 处理处理:1.用清洁干布擦拭漏液监测器用清洁干布擦拭漏液监测器.2.清理卡盘上的六个机械卡爪清理卡盘上的六个机械卡爪.Copyright 2007 Haemonetics Corporation.Haemonetics,Infonal,cardioPAT,Cell Saver,OrthoPAT,SmartSuction,SmartSuction Harmony,and SmartSuction Solo are trademar